18 - MicroTimer 2400
Appendix
Connections & Schematics
Overview
There may be up to 2 units, that can be connected (A & B) independent of each other on the two relays (E & F). These
relays are potential-free or 'dry', ie simply switches that are switched from inside the machine but have no power is feed.
Item J: RFI-CAP
Schematic:
Radio Frequency Interference Capacitor
(RFI-Cap)
This is used in order to filter out the
interference, if the device is connected to the
main power.
#
Descr iption
Remar ks
A
Third-party dev ice - O utput 2
D ev ice of the third-party that needs to sw itched on, is
connected to O utput 2. O utput 2 is sw itched only by the main
time function (
F 1
).
B
Third-party dev ice - O utput 1
D ev ice of the third-party that needs to sw itched on, is
connected to O utput 1. O utput 1 is sw itched by the prior time
(
F 2
), main time (
F 1
) and post time (
F 3
)
functions.
C
C oin A cceptor
These are not used in the M icroTimer
D
Remote Button P rint
This print is used to access the three button from a greater
distance (maximum 50 meters).
E
O utput 2
O utput 2 is exclusiv ely sw itched by the main time function
(F 1).
The relay s are potential free or 'dry ', ie they are simply
sw itches that are controlled from w ithin the M icroTimer, but no
pow er is fed through them.
F
O utput 1
O utput 1 is sw itched by the prior time (F 2), main time (F 1) and
post time (F 3) functions.
The relay s are potential free or 'dry ', ie they are simply
sw itches that are controlled from w ithin the M icroTimer, but no
pow er is fed through them.
G
230V C onnectors
S ecured by the fuse.
H
F use
500 M a-T F use
I
24V C onnectors
The 24V connection is not secured by a fuse!
J
E arth w ire, RF I-C ap
C onnect the ground w hen using the 230V connection to ground
the RF I-C ap. S ee also the RF I C ap diagram abov e.
K
230V C onnection
230V P ow er feed of the Remote Button P rint
1
U p Button
A lso used for; Bridging the main time (
F A
), P rior Time
(
F 2
), M ain Time (
F 1
), Reset (
F B
-
F E
) /
C lean (
F 9
)
2
S tart Button
A lso used for the E xternal start (P C ) (
P 1
)
3
D ow n Button
A lso used for; Read out counter v alues (
F B
-
F E
), M ain
Time Reduction (
P 7
), A fter S tart (
P 2
), Reset
(
F B
-
F E
)
8
9
8
9
11
9
8
11
12
10
12
11
12
13
13
11
12
Содержание MicroTimer 2400
Страница 1: ...2019 Inepro B V All rights reserved Technical Manual MicroTimer 2400 MicroTimer 2400...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 7: ...Introduction PartI...
Страница 10: ......
Страница 11: ...Possebilities PartII...
Страница 13: ...Settings PartIII...
Страница 21: ...Specifications PartIV...
Страница 23: ...Appendix PartV...
Страница 28: ......