Function F6, Service indicator 1
(
ECOS module EM-06)
Function
T he maximum amount of pr ogr ammable r unning hour s befor e a r evision ser vice
is r equir ed. T his r egister will count down per 1 0 0 0 minutes of r elay 1 activity.
T he value of this r egister r epr esents the number x 1 0 0 0 minutes, e.g. 5 =
5 0 0 0 minutes.
When the counter r eaches zer o, the
message will appear on the display.
T his is the standar d message to indicate that a r evision “ser vice” is r equir ed.
V alue
Descr iption
Default
1-254
N umber of serv ice minutes before serv ice on dev ice is required.
When this counter has counted dow n to zero (serv ice counter = 0) the
M icoTimer® w ill display
. N umber of minutes = S etting x 1000
minutes.
0
255
D isabled
N ote:
The timer w ill keep running as usual. To reset, simply set the v alue to a
v alue higher then '0'.
Function F7, Service indicator 2
(
ECOS module EM-07)
Function
T he maximum amount of pr ogr ammable r unning hour s befor e a r evision ser vice
is r equir ed. T his r egister will count down per 1 0 0 0 minutes of r elay 1 activity.
T he value of this r egister r epr esents the number x 1 0 0 0 minutes, e.g. 5 =
5 0 0 0 minutes.
When the counter r eaches zer o, the
message will appear on the display.
T his is the standar d message to indicate that a r evision “ser vice” is r equir ed.
V alue
Descr iption
Default
1-254
N umber of serv ice minutes before serv ice on dev ice is required.
When this counter has counted dow n to zero (serv ice counter = 0) the
M icoTimer® w ill display
and is inhibited until the counter is reset.
N umber of minutes = S etting x 1000 minutes.
0
255
D isabled
N ote:
To reset, simply set the v alue to a v alue higher then '0'.
Function F8, Buzzer setting
(
ECOS module EM-08)
Function
Buzzer Setting
Setting
Descr iption
Default
N ote:
This setting is not applicable in this dev ice.
0
Function F9, Clean Function
(
ECOS module EM-09)
Function
By means of this function it is possible to for ce the cleaning of a connected
device. A fter the posted time the M icoT imer ® does not accept any fur ther coin
anymor e. T his blockage can be r aised by pr essing the inter nal or exter nal up
key for 3 seconds. T o indicate the necessity of cleaning
will appear
inter mittently on the M icoT imer ® display.
Setting
Descr iption
Default
00
C lean function off
1
01
C lean function on.
Содержание MicroTimer 2400
Страница 1: ...2019 Inepro B V All rights reserved Technical Manual MicroTimer 2400 MicroTimer 2400...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 7: ...Introduction PartI...
Страница 10: ......
Страница 11: ...Possebilities PartII...
Страница 13: ...Settings PartIII...
Страница 21: ...Specifications PartIV...
Страница 23: ...Appendix PartV...
Страница 28: ......