Transportation, Installation, Commissioning
LL1602.10043 - 04.08.2014
ABC
PREPARATIONS
External data transfer
Data lines must not run directly next to power lines.
When you intend to transmit data from/to an external computer or memory, appro-
priate metal ducts for the data lines must be installed.
Media to be provided
– Hydraulic oil
1)
– Lubricating oil
1)
– Appr. 1 kg heavy duty grease for chucks
– Coolant
For types of lubricating oil, hydraulic oil, grease and coolant as well as filling
amounts see chapter "Maintenance Instructions" and the "machine installation dia-
gram" in chapter "Working Data".
Attention!
Only hydraulic oil according to ISO 4406 with a purity 15/12 (10 µm
absolute) may be filled. Hydraulic oil: HLP 32; HLPD 32; VG 32.
Lubrication oil CG 68; G68
1)
Machine supplied with tank filled.