- Renewing the pneumatically pilot-controlled cooling lubricant valves
Orientation
In the course of the machine's operating time, internal wear of the pneumatically
pilot-controlled cooling lubricant valves may occur, with the result that cooling
lubricant may penetrate the pneumatic control lines. To avoid consequential
damage, INDEX recommends replacing these valves after 5 years.
Requirement
Due to different requirements and/or specifications of the respective
manufacturers, be sure to review the respective manufacturer's
documentation!
Power off the machine to depressurize the pneumatic system and
secure against accidental switching on.
Procedure
1. Renew valves.
Maintenance Summary - 5 Years
105
Maintenance Instructions
ABC.2
DIE244EN - 15.08.2022
Содержание ABC 2 Series