Limited Warranty 

 

Warranty 

 
Inciner8 Ltd, warrantor, warrants to the original purchaser of one (1) year from date of 
purchase or delivery to original purchaser, products manufactured / supplied by it which are 
installed and operated according to Warrantor’s instructions that are furnished and/or are 
available to purchaser upon request, and installed according to other applicable federal, state, 
government and local codes or regulations and upon substantiation that said products were 
installed correctly, were not abused and are defective. The exact nature of said warranty and 
exclusive remedy for breach by warrantor is as follows:- 
 
Warrantor will refund or credit to purchasers account an amount equal to the original 
purchase price or at warrantors option repair or replace at Warrantors expense, products 
found to be defective in workmanship or material. If a problem occurs which the purchaser 
believes is covered by his warranty, then the purchaser shall contact the seller giving the 
seller sufficient information to enable a resolution of the problem. If the seller is unable or 
unwilling to resolve the problem and the purchaser is still convinced that it is covered by the 
warranty the purchaser should contact the manufacturer at the address listed in the following 
paragraph and provide a description in writing of the problem and the attempts made to 
resolve it. ‘Seller’ as used herein shall mean the dealer or distributor from whom the product 
was purchased. 
 
No product or part thereof may be returned pursuant to this warranty without first receiving 
specific written permission to do so. All requests should be addressed to Inciner8 Ltd, Unit 9, 
Shakespeare House, 37-39 Shakespeare Street, Southport PR8 5AB, United Kingdom, 
requesting specific authority for returning merchandise pursuant to this warranty with reasons 
for the request. 
 

Limitations 

 
Products which are abused or neglected are not covered under this warranty, including 
overfilling units or covering burner outlets (please refer to manual for usage instructions). 
Warrantor shall not be responsible for the costs of removal or reinstallation of its products and 
shall not be liable for transportation costs to and from its plant. Further. Warrantor shall not be 
liable for replacement, repair or refund for component parts not manufactured by it. 
 
Use of parts for modification or repair of the unit or any component not authorised or supplied 
by Inciner8 Ltd, specifically for this product shall void the warranty. 
 
Implied warranties of merchantability and fitness for a particular purpose are limited to the 
same period of time as this express limited one (1) year warranty and are specifically 
disclaimed thereafter. 
 

Inciner8 

Ltd shall not be liable for any incidental, consequential, special or 

contingent damages or expenses arising directly or indirectly from any defect 
in the product hereby warranted. 

 
The warranty shall be VOID if solvents or other highly inflammable fluids such as but not 
limited to Benzene, methylethyl, ketones, toluene, xylene or naptha are burned in or mixed 
with oil for burning in used oil fired burning heaters or furnaces. 
 
For those states that do not allow limitations on how long an implied warranty lasts, this 
limitation may not apply. Similarly, for those states that do not allow the exclusion or 
limitations of incidental or consequential damages, the above exclusions of indirect, 
incidental, or consequential damages may not apply. 
 
This warranty gives you specific legal rights and you may also have other rights, which vary 
from, state to state. 
 
Inciner8 Ltd is not responsible for any undertaking, representation, or warranty made by any 
dealer, distribution, or other persons, beyond those expressly set forth in this warranty. 

Содержание A400-G

Страница 1: ...r Model A400 G Operators Manual Important Failure to cure refractory Before using will void warranty see refractory curing procedure Tampering with orifices in the burner will void warranty Revised January 2005 1 ...

Страница 2: ...ifications Page 4 Service installation sheet Page 5 Site plan fitting Page 6 Assembly Instructions Page 7 Commissioning start up procedures Page 8 Operator instructions Page 8 Refractory Curing Procedure Page 9 Inspection Servicing Page 10 Fitting Chimney through roof dia Page 11 Warranty Page 12 ...

Страница 3: ...n to composting Studies found costs of incineration to be very favourable against other methods of disposal SANITARY Waste can be destroyed as fast as it accumulates Nothing is left to spread disease or to attract rodents and flies CONVENIENT Fill the chamber and turn on the burner No watching required since timer automatically shuts down burner Alternative methods frequently require more time to ...

Страница 4: ...HZ 10 amp LP 3 0 GPH 11 4 l hr Natural 275 CFH 7 8 m3 hr FUEL CONSUMPTION Fuel Oil 3 0 GPH 13 2 l hr Secondary Chamber DEFRA Approved models only Chamber size outside Width 43cm Height 200cm Length 66cm Chamber Volume 44 cubic meters We reserve the right to alter specifications without prior notice Installation Must be installed in accordance with local codes and ordinances subject to regulatory a...

Страница 5: ...5 Inciner8 Incinerator Model A400 Installation Location Installed by Date Sold By Service Record Date Comments ...

Страница 6: ...n and inspection Electrical Service 220 Volt 50 60 HZ 10 Amp 1 Electrical service can be supplied by plugging into the cordset NOTE Polarity must be maintained or the burners will not operate If burners lock out after approximately 5 seconds and the blower continues to operate then the polarity is incorrect It should be corrected at the power source not in the incinerator control Fuel Install gas ...

Страница 7: ...nuts 3 Position the stack screen over the top of the stack and attach with the 3 x screws Primary Chamber 1 Bolt the door latch to the primary chamber with 4 x 3 8 16 x 1 bolts and nuts 2 Bolt the counter weight to the counter weight arm with 2 x 5 16 18 x 7 1 2 bolt and nuts IT IS VERY IMPORTANT THAT THE DOOR IS NICELY BALANCED AND MAKES A FIRM SEAL AROUND THE WHOLE CASE WHEN CLOSED SHUT FAILURE ...

Страница 8: ...ty 5 Once the temperature reaches in excess of 850 deg C displayed on the temperature readout select the Off setting on the switch 6 NOW LOAD THE INCINERATOR Keep the waste 20cm away from the burner port 7 Lock the unit door to ensure that no one can inadvertently access the chamber during the burn 8 START BURNER by setting the switch to incinerate for the desired burn time A full load will normal...

Страница 9: ...utes Burn 15 minutes Cool 15 minutes Burn 30 minutes Cool 15 minutes Burn 30 minutes Cool 15 minutes Burn 1 hour Cool 15 minutes Burn 1 hour Cool 15 minutes Burn 2 hours Cool 15 minutes Burn 3 hours Total Time 12 hours There will be hairline cracks and minor scaling of the refractory when curing is completed This is a normal result of the curing process ...

Страница 10: ...000 hours or annually whichever is the sooner Service Inspection procedures should include 1 Check for leaks in all pipe work and gas supply 2 Check for leak tightness of the unit ensuring all waste gas travels up the chimney output 3 All safety shut off valves and safety guards should be inspected 4 A temperature and combustion analysis should be performed to ensure that there is no deterioration...

Страница 11: ...11 ...

Страница 12: ...ty for returning merchandise pursuant to this warranty with reasons for the request Limitations Products which are abused or neglected are not covered under this warranty including overfilling units or covering burner outlets please refer to manual for usage instructions Warrantor shall not be responsible for the costs of removal or reinstallation of its products and shall not be liable for transp...

Отзывы: