30
IM483 Operating Instructions Revision R032306
31
IM483 Operating Instructions Revision R032306
4 L e a d M o t o r s
4 lead motors are the least flexible but easiest to wire. Speed and torque
will depend on winding inductance. In setting the driver output current,
multiply the specified phase current by 1.4 to determine the peak output
current.
Figure 6.6: 4 Lead Motor Connections
PHASE A
PHASE A
PHASE B
PHASE B