78
IM483 Operating Instructions Revision R032306
79
IM483 Operating Instructions Revision R032306
Cable length, wire gauge and power conditioning devices play a major
role in the performance of your IMS Driver and Motor.
NOTE: The length of the DC power supply cable between the IMS Driver
and the Motor should not exceed 50 feet.
Example A demonstrates the recommended cable configuration for the
IMS Driver to Motor cabling under 50 Feet long. If cabling of 50 feet or
longer is required, the additional length can be gained with the cable
configuration in Example B.
Correct AWG wire size is determined by the current requirement plus
cable length. Please see the IMS Driver to Motor Cable AWG Table in this
Appendix.
����������������������
������������������
��������������������������
���������������
������������������������������������
�������
�����
������������
�����������������
�������
�������
�������
�������
�������
�������
�������
�������
E x a m p l e A - C a b l i n g U n d e r 5 0 F e e t , I M S
D r i v e r t o M o t o r
R e c o m m e n d e d C a b l e C o n f i g u r a t i o n s :
I M S D r i v e r t o M o t o r