IM483 Operating Instructions Revision R032306
1 Ampere (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
20 20 18 18
16
2 Amperes (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
20 18 16 14
14
3 Amperes (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
18 16 14 12
12
4 Amperes (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
18 16 14 12
12
5 Amperes (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
16 16 14 12
12
6 Amperess (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
14 14 14 12
12
7 Amperess (Peak)
Length (Feet)
Minimum AWG
10 25 50* 75* 100*
12 12 12 12
12
* Use the alternate method illustrated in Example B
when cable length is
≥
50 feet.
IMS Driver to Motor Cable AWG Table
Driver to Motor Supply Cable Wire Size
NOTE:
These recommendations will provide optimal
protection against EMI and RFI. The actual cable type,
wire gauge, shield type and filtering devices used are de-
pendent on the customer’s application and system.
NOTE:
Always use Shielded/Twisted Pairs for the IMS
Driver DC Supply Cable, the AC Supply Cable and the IMS
Driver to Motor Cable.