44
IM483 Operating Instructions Revision R032306
45
IM483 Operating Instructions Revision R032306
MSEL0
MSEL1
MSEL2
MSEL3
ON
SW1
P1
+VDC
CONTROLLER
OUTPUT
R
1⁄4 W 1%
LIMIT
+VDC
5
10
12
15
24
-----
681
1000
1300
2670
R
LIMIT
Opto Supply P1:4
Reset P1:6
Low Pulse
Will Reset
Driver
O p e n C o l l e c t o r I n t e r f a c e
Figure 7.7 shows an open collector interface connected to the reset input.
This interface method may be used with any of the logic inputs. Remem-
ber that a current limiting resistor is required if an opto supply voltage
greater than +5 VDC is used.
Figure 7.7: Open Collector Interface
T T L I n t e r f a c e
Figure 7.8 shows a TTL device connected to the enable input. This inter-
face method may be used with any of the logic inputs.
Figure 7.8: TTL Interface
MSEL0
MSEL1
MSEL2
MSEL3
ON
SW1
P1
+5 VDC
CONTROLLER
OUTPUT
Opto Supply P1:4
Enable P1:5