8-2
Maintenance and Inspection
8
Remarks: Remove dust using cleaning cloth
which is chemically neutral. Use a vacuum
cleaner to remove dust.
Common
1) Check if bolts and screws are tight
1) Retighten
1), 2), 3)
and not missing.
2), 3) Visual
No abnormalities
2) Check the devices and insulators for
inspection
deformation, cracks, breakage and
discoloration caused by overheat
and deterioration.
3) Check for dust.
Conductor
1) Check the conductor for discoloration
1), 2) Visual
1), 2)
and wire
and distortion caused by overheat.
inspection
No abnormalities
2) Check the sheath of the cable for
cracks and discoloration.
Terminal
Damage
Visual inspection
No abnormalities
block
Smoothing
1) Check for electrolyte leakage,
1), 2)
1), 2)
capacitor
discoloration, cracks and swelling of
Visual inspection
No abnormalities
the case.
3) Monitor H42 Life
3) Capacitance>
2) Check for safety valve protrusion.
judgment and
(Initial value) x
=
measure with
0.85
3) Measure the capacitance
capacitance probe
Resistor
1)Check for odor caused by overheat
1) Smelling and
1) No abnormalities
and cracked insulator.
visual inspection
2) Within ± 10% of
2) Check for broken wire.
2) Visual inspection
displayed resistance
or measurement
with multimeter under
disconnection of
one lead
Transformer
Check for abnormal noise
Hearing, visual and
No abnormalities
and odor.
smelling inspection
Relay
1) Check for chatters during operation.
1) Hearing
1),2)
2) Check for rough contacts.
inspection
No abnormalities
2) Visual inspection
Control
1) Check for loose screws and
1) Retighten.
1),2),3),4)
printed
connectors.
2) Smelling and
No abnormalities
circuit
2) Check for odor and discoloration.
visual inspection
board,
3) Check for cracks, breakage,
3), 4) Visual
connector
deformation and rust.
inspection
4) Check the capacitors for electrolyte
leaks and deformation.
Cooling fan
1) Check for abnormal noise and
1) Hearing and
1) Smooth rotation
excessive vibration.
visual inspection,
2),3)
2) Check for loose bolts.
or turn manually
No abnormalities
3) Check for discoloration caused by
(be sure to turn
overheat.
the power off)
4) Check that fan is operating when
2) Retighten.
power is restored.
3) Visual inspection
4) Life judgment
based on
maintenance data*
Ventilation
Check the heat sink, intake and
Visual
No abnormalities
path
exhaust ports for clogging and foreign
inspection
matter.
Main circuit
Main circuit
Control circuit
Cooling system
Содержание VXSM150-1
Страница 3: ......
Страница 41: ...5 12 Selecting Functions 5 Frequency setting block diagram ...
Страница 45: ...5 16 Selecting Functions 5 Note The chain line indicates the motor speed ...
Страница 71: ...7 1 Troubleshooting 7 7 Troubleshooting 7 1 When Protective Function Activates 1 Overcurrent ...
Страница 72: ...Troubleshooting 7 2 7 2 Overvoltage 3 Undervoltage ...
Страница 77: ...7 7 Troubleshooting 7 3 The motor loses speed during acceleration 4 Excessive heat generation from motor ...