Selecting Functions
5-9
5
Min.
Factory
Name
Setting range
unit
setting
A01
Maximum frequency 2
50 to 400Hz
1Hz
50
X
0
A02
Base frequency 2
25 to 400Hz
1Hz
50
X
0
A03
Rated voltage
2 0V, 80 to 240V(200V class)
1V
230
X
0
(at base frequency 2) 0V,160 to 480V(400V class)
400
A04
Maximum voltage
2 80 to 240V (200V class)
1V
230
X
0
(at maximum
160 to 480V(400V class)
400
frequency 2)
A05
Torque boost 2
0,1,2,3 to 31
1
0
0
A06
Electronic thermal
0: Inactive
1
1
0
overload relay
1: Active (for general purpose motors)
for motor 2 (Select)
2: Active (for inverter motors)
A07
(level)
20 to 135% of the rated inverter current
0.01A
rated
6
motor current
A08
(Thermal time
0.5 to 10 min.
0.1min
5.0
2
constant)
A09
Torque vector control
0:Inactive
1
0
X
0
2
1:Active
A10
Number of motor
2 to 14
2
4
X
0
2 poles
A11
Motor 2 (Capacity)
0.01 to 5.5kW (4.0kW or smaller)
0.01kW
Nominal kW
X
4
0.01 to 11.00kW(5.5/7.5kW)
applied
motor kW
A12
(Rated current)
0.00 to 99.9A
0.01A
standard
X
6
rating
A13
(Tuning)
0: Inactive
1: Active (%R1, %X)
2: Active (%R1, %X, Io)
1
0
X
12
A14
(Online tuning)
0: Inactive, 1: Active
1
0
X
0
A15
(No-load current)
0.00 to 99.9A
0.01A
standard
X
6
rating
A16
_R1 setting_
0.00 to 50.00%
0.01%
standard
4
rating
A17
_X setting_
0.00 to 50.00%
0.01%
standard
4
rating
A18
(Slip compensation
0.00 to 15.00Hz
0.01Hz
0.00
4
control 2)
A19
(Slip compensation
0.01 to 10.00s
0.01s
0.50
4
response time 2)
Function code
Change during
operation
RS485 Data format
User setting
Description of change during operation
: The data changed by the or key takes
effect on the inverter operation. However,
press the key to store the new data.
V
V
: Press the or key to change the data.
The new data takes effect after the key is
pressed to store the data.
X : The data can be changed only while the
inverter is stopped.
V
V
FUNC
DATA
FUNC
DATA
A: Alternative motor parameters
Содержание VXSM150-1
Страница 3: ......
Страница 41: ...5 12 Selecting Functions 5 Frequency setting block diagram ...
Страница 45: ...5 16 Selecting Functions 5 Note The chain line indicates the motor speed ...
Страница 71: ...7 1 Troubleshooting 7 7 Troubleshooting 7 1 When Protective Function Activates 1 Overcurrent ...
Страница 72: ...Troubleshooting 7 2 7 2 Overvoltage 3 Undervoltage ...
Страница 77: ...7 7 Troubleshooting 7 3 The motor loses speed during acceleration 4 Excessive heat generation from motor ...