9-21
Specifications
9
(2)Functions for standard frame (monitor data)
Name
Command
Function type
Data and operation
type
character and
character
number
Frequency
R
M01
±20000d/fmax (Max. frequency)
(Final value)
Frequency
R
M05
100=1.00Hz (Value multiplied by 100)
command value
The current frequency setting is returned.
Calculated torque
R
M07
100% (rated torque) / ± 10000 (value multiplied
value
by 100)
Torque current
R
M08
100% (rated current) / ± 10000
(value multiplied by 100)
Output frequency
R
M09
100=1.00Hz
(Value multiplied by 100; special additional data: sign)
The current output frequency is returned.
Motor output
R
M10
100% (rated output) / ± 10000
(power
(value multiplied by 100)
consumption)
Output current
R
M11
100 = 1% of rated inverter current
The current output current is returned in the ratio to
the rated current.
Output voltage
R
M12
10=1V
Operation R
M13
bit15:RESET 1:ON,0:OFF
command
bits 14 to 5: Fixed to 0
bit6:X5 1:ON, 0:OFF
bit5:X4 1:ON, 0:OFF
bit4:X3 1:ON, 0:OFF
bit3:X2 1:ON, 0:OFF
bit2:X1 1:ON, 0:OFF
bit 1: REV (reverse rotation command)
1:ON,0:OFF
bit 0: FWD (forward rotation command)
1:ON,0:OFF
The final command value including the state of the
actual control terminal of the inverter is returned.
Operation status
R
M14
bit 15: Function code data being written
bit 12: 1: Communication valid
bit 11: 1: Batch failure (tripping)
bit 10: 1: During deceleration
bit 9: 1: During acceleration
bit 8: 1: Current limit operation
bit 7: 1: Voltage limit operation
bit 6: 1: Torque limit operation
bit 5: 1: DC link voltage established
bit 4: 1: During braking
bit 3: 1: During output shutoff
bit 2: 1: During DC braking
bit 1: 1: During reverse rotation
bit 0: 1: During forward rotation
General purpose
R
M15
bit 1: Y2; active upon "1"
output terminal
bit 0: Y1; active upon "1"
Table 9-4-6 Standard frame (monitor data)
Содержание VXSM150-1
Страница 3: ......
Страница 41: ...5 12 Selecting Functions 5 Frequency setting block diagram ...
Страница 45: ...5 16 Selecting Functions 5 Note The chain line indicates the motor speed ...
Страница 71: ...7 1 Troubleshooting 7 7 Troubleshooting 7 1 When Protective Function Activates 1 Overcurrent ...
Страница 72: ...Troubleshooting 7 2 7 2 Overvoltage 3 Undervoltage ...
Страница 77: ...7 7 Troubleshooting 7 3 The motor loses speed during acceleration 4 Excessive heat generation from motor ...