5-4
Selecting Functions
5
Min.
Factory
Name
Setting range
unit
setting
E01
X1 terminal function
0: Multistep frequency selection [SS1]
0
X
0
1: Multistep frequency selection [SS2]
2: Multistep frequency selection [SS4]
3: Multistep frequency selection [SS8]
E02
X2 terminal function
4:Acceleration/deceleration time
1
X
0
selection [RT1]
5: 3-wire operation stop command [HLD]
6: Coast-to-stop command [BX]
7: Alarm reset [RST]
E03
X3 terminal function
8: Trip command(External fault) [THR]
2
X
0
9: Frequency setting 2/1 [Hz2/Hz1]
1
10: Motor 2/ Motor 1 [M2/M1]
11: DC brake command [DCBRK]
12: Torque limiter 2/Torque limiter 1
E04
X4 terminal function
[TL2/TL1]
6
X
0
13: UP command [UP]
14: DOWN command [DOWN]
15: Write enable for KEYPAD [WE-KP]
E05
X5 terminal function
16: PID control cancel [Hz/PID]
7
X
0
17: Inverse mode changeover [IVS]
(terminal 12 and C1)
18: Link enable [LE]
E10
Acceleration time 2
0.01 to 3600s
0.01s
10.0
6
E11
Deceleration time 2
10.0
6
E16
Torque limiter 2
20 to 200%
1%
180
0
(Driving)
999: Inactive
E17
(Brake)
0%: Automatic deceleration control,
20 to 200%
1%
150
0
999: Inactive
E20
Y1 terminal function
0: Inverter running [RUN]
0
X
0
1: Frequency equivalence [FAR]
2: Frequency level detection [FDT]
3: Undervoltage detection signal [LV]
4: Torque polarity [B/D]
1
E21
Y2 terminal function
5: Torque limiting [TL]
7
X
0
6: Auto restarting [IPF]
7: Overload early warning [OL]7
8:Life time alarm [LIFE]
9:Frequency level detection 2 [FAR2]
E29
Frequency level
0.01 to 10.0s
0.01s
0.1
6
detection delay
E30
FAR function signa
l0.0 to 10.0Hz
0.1Hz
2.5
2
(Hysteresis)
E31
FDT function signal
0 to 400Hz
1Hz
50
0
(Level)
E32
(Hysteresis)
0.0 to 30.0Hz
0.1Hz
1.0
2
E33
OL function signal
0: Electronic thermal overload relay
(Mode select)
1: Output current
1
0
0
E34
(Level)
20 to 200% of the rated inverter current
0.01A
rated
motor
current 6
E35
(Timer )
0.0 to 60.0s
0.1s
10.0
2
E40
Display coefficient
A
0.00 to 200.0
0.01
0.01
6
E41
B
0.00 to 200.0
0.01
0.00
6
E42
LED display filter
0.0 to 5.0s
0.1s
0.5
2
Function code
Change during
operation
RS485 Data format
User setting
E: Extension terminal functions
Содержание VXSM150-1
Страница 3: ......
Страница 41: ...5 12 Selecting Functions 5 Frequency setting block diagram ...
Страница 45: ...5 16 Selecting Functions 5 Note The chain line indicates the motor speed ...
Страница 71: ...7 1 Troubleshooting 7 7 Troubleshooting 7 1 When Protective Function Activates 1 Overcurrent ...
Страница 72: ...Troubleshooting 7 2 7 2 Overvoltage 3 Undervoltage ...
Страница 77: ...7 7 Troubleshooting 7 3 The motor loses speed during acceleration 4 Excessive heat generation from motor ...