43
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
3.26 COMBUSTION PARAMETERS.
Victrix Pro 80 2ErP
G20
G31
Gas nozzle diameter
mm
12.70
8.50
Supply pressure
mbar (mm H
2
O)
20 (204)
37 (377)
Flue flow rate at nominal heat output
kg/h
114
120
Flue flow rate at min heat output
kg/h
13
13
CO
2
at Q. Nom./Min.
%
9.95 / 8.95
10.60 / 9.75
CO with 0% O
2
at Nom./Min. Q. Nom./Min.
ppm
233 / 4
175 / 4
NO
X
at 0% of O
2
at Q. Nom./Min.
mg/kWh
34 / 1
65 / 6
Flue temperature at nominal output
°C
62
61
Flue temperature at minimum output
°C
43
42
Victrix Pro 100 2ErP
Gas nozzle diameter
mm
11.30
8.40
Supply pressure
mbar (mm H
2
O)
20 (204)
37 (377)
Flue flow rate at nominal heat output
kg/h
146
148
Flue flow rate at min heat output
kg/h
16
16
CO
2
at Q. Nom./Min.
%
9.40 / 9.00
10.60 / 10.10
CO with 0% O
2
at Nom./Min. Q. Nom./Min.
ppm
210 / 5
230/ 1
NO
X
at 0% of O
2
at Q. Nom./Min.
mg/kWh
62 / 8
67 / 10
Flue temperature at nominal output
°C
53
54
Flue temperature at minimum output
°C
45
45
Victrix Pro 120 2ErP
Gas nozzle diameter
mm
16.50
9.70
Supply pressure
mbar (mm H
2
O)
20 (204)
37 (377)
Flue flow rate at nominal heat output
kg/h
174
183
Flue flow rate at min heat output
kg/h
19
19
CO
2
at Q. Nom./Min.
%
9.80 / 9.00
10.60 / 10.00
CO with 0% O
2
at Nom./Min. Q. Nom./Min.
ppm
257 / 1
220 / 1
NO
X
at 0% of O
2
at Q. Nom./Min.
mg/kWh
95 / 9
77 / 13
Flue temperature at nominal output
°C
56
56
Flue temperature at minimum output
°C
46
46