- The data relevant to domestic hot water perfor-
mance refer to a dynamic inlet pressure of 2 bar
and an inlet temperature of 15°C; the values are
measured directly at the boiler outlet consider-
ing that to obtain the data declared mixing with
cold water is necessary.
- * Yields refer to the lower heating value.
3.21 TECHNICAL DATA.
Domestic hot water nominal heat input
kW (kcal/h)
33,0 (28400)
Central heating nominal heat input
kW (kcal/h)
33,0 (28400)
Minimum heat input
kW (kcal/h)
7,3 (6279)
Domestic hot water nominal heat output (useful)
kW (kcal/h)
32,0 (27520)
Central heating nominal heat output (useful)
kW (kcal/h)
32,0 (27520)
Minimum heat output (useful)
kW (kcal/h)
6,9 (5934)
*Effective thermal efficiency 80/60 Nom./Min.
%
96,9 / 94,5
*Effective thermal efficiency 50/30 Nom./Min.
%
104,7 / 105,8
*Effective thermal efficiency 40/30 Nom./Min.
%
107,3 / 107,3
Casing losses with burner On/Off (80-60°C)
%
0,80 / 0,20
Heat loss at flue with burner On/Off (80-60°C)
%
0,02 / 2,90
Central heating circuit max. operating pressure
bar
3
Maximum heating temperature
°C
90
Max. adjustable central heating temperature
°C
25 - 85
Min. adjustable central heating temperature
°C
25 - 50
System expansion vessel total volume
l
10,8
Heating expansion vessel pre-charge
bar
1,0
Total volume domestic hot water expansion vessel
l
4,1
Domestic hot water expansion vessel pre-charge
bar
3,5
Appliance water content
l
6,7
Head available with 1000 l/h flow rate in direct zone
kPa (m H
2
O)
28,8 (2,94)
Head available with 1000 l/h flow rate in mixed zone
kPa (m H
2
O)
35,0 (3,57)
Hot water production useful heat output
kW (kcal/h)
32,0 (27520)
Domestic hot water adjustable temperature
°C
10 - 60
Domestic hot water circuit min. pressure (dynamic)
bar
0,3
Domestic hot water circuit max. operating pressure
bar
8,0
Flow rate capacity in continuous duty (∆T 30°C)
l/min
16,0
Domestic hot water performance classification according to N 13203-1
Weight of full boiler
kg
254
Weight of empty boiler
kg
127,9
Electrical connection
V/Hz
230 / 50
Nominal power absorption
A
1,16
Installed electric power
W
168
Boiler circulating pump absorbed power
W
58
EEI value
-
≤ 0,21 - Part. 2
Zone pump absorbed power
W
2 x 37
EEI value
-
≤ 0,21 - Part. 2
Fan power absorbed power
W
28
Equipment electrical system protection
-
IPX5D
Max temperature of combustion products
°C
75
NO
X
class
-
6
Weighted NO
X
mg/kWh
33
Weighted CO
mg/kWh
18
Type of appliance
C13 / C33 / C43 / C53 / C83 / C93 / B33 / B53p
Category
II 2H3P - I 3P