13
3
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
1.7 INSTALLATION ON A FLAT ROOF.
Never remove the cover sheet if you have not fini-
shed installing the panel and if the collector has not
been filled. The SOLARSMART solar collector with
integrated storage was not designed to be exposed to
sunlight when empty.
Do not move or force the solar collector using the threaded con-
nections or the caps.
PLACE AND POSITION.
Select an installation place that makes it possible to
reduce accidental loads (wind, snow, etc...) to which
the system can be subjected. As an example, avoid
areas where vortexes form, or which are subjected to
wind because of thermal inversion. If situations like
this are present, get a structural technician to check
the maximum structure loads.
If installing on a flat roof, position the collector at least 1-2 metres
from the edge.
If installing on the ground, position the collector at least 1-2 metres
from any obstacles that are present.
Direct the transparent surface as close to the south as possible.
If deviated slightly towards the east or the west, the system still
works in a satisfactory manner. Choose an installation area where
the panel remains in the sunlight for as long as possible. Nearby
obstacles (trees, buildings, etc...) can temporarily shade the system
and reduce (even greatly) its performance.
If positioning several collectors behind each other, do not let them
shade each other. To prevent this, keep enough distance between
them to permit radiation without shade when the sun is at an
angle of 15° from horizontal.
For the system to operate correctly, install the collector
at an angle of between 15° and 60°. The supplied sup-
ports, if placed on a flat surface, give 45° installation.
The anchor points must all be on the same supporting
surface. Any torsion force caused by supporting points that are
not aligned can damage the system.
The longest side of the collector must always be supported by the
surface. Do not install the collector with the short side (where the
connections are) against the surface.
DO NOT TURN THE COLLECTOR UPSIDE
DOWN.
The outflow should be positioned at the
top, and can be identified by its red cap (inflow at the
bottom, identified by a blue cap). Correct operation
cannot be guaranteed if the system is installed upside
down.
Necessary items:
n.2 spanners 13 mm, individual PPE (helmet,
gloves, goggles, etc...)
Danger! The screws for fixing the supports to the roof
are not supplied. They must be obtained by the instal-
ler, depending on the specific fixing conditions and
following the indications of the structural technician.
Содержание 3.029660
Страница 2: ......
Страница 18: ...18 7h 7g 7d 7e 7f 5 6 7 8 9 A A 13 13 INSTALLER USER MAINTENANCE TECHNICIAN...
Страница 33: ...33...
Страница 34: ...34...