1.22 INDICATIONS ON USING ELECTRIC RESISTORS
The solar collector with SOLARSMART built-in storage can be
unlimitedly used, with the exception of the areas at risk of ice.
Should the risk of the temperature falling below 0°C be present,
the “SOLARSMART” solar collector with integrated storage must
be emptied and covered with the PVC cover sheet.
Alternatively, and always with outdoor temperatures of not below
-5°C, the antifreeze electric resistor can be installed.
To prevent the formation of ice inside the piping, in addition to
the antifreeze electric resistor, we recommend insulating the water
supply lines, especially the outdoor sections.
The 1 and 2 kW electric resistors should be used if the “SO-
LARSMART” solar collector with integrated storage is connected
directly to the user, without the addition of a boiler downstream.
In periods of less irradiation and colder months, the 1 and 2 kW
electric resistances serve as heat integration in order to bring the
water temperature in the storage tank to values close to those of
use (heating of the top part only).
The electric resistor settings were selected to optimise
system duration and operation, and were set in the
factory.
Altering these values is considered as tampering with
the product, which can cause possible faults and da-
mage; in this case the manufacturer will not recognise
any guarantee rights.
To guarantee correct resistor operation and prevent
damaging the SOLARSMART solar collector with
integrated storage, only the types of electric resistor
proposed by the manufacturer can be used. No gua-
rantee rights will be recognised if other types of seals
or additions are used.
If any antifreeze or integration resistors have been
installed, in the event of emptying the collector these
must be deactivated.