Immergas 3.029660 Скачать руководство пользователя страница 6

6

Dear Customer,

our compliments for having chosen a top-quality Immergas product, able to ensure well-being and safety for a long period of time. As an

Immergas Customer, you can also count on a qualified after-sales service, prepared and updated to guarantee constant efficiency of your

boiler. Read the following pages carefully: you will be able to draw useful tips on the correct use of the device, compliance of which will

confirm your satisfaction with the Immergas product.

For any assistance and scheduled maintenance please contact Authorised After-Sales centres: they have original spare parts and are

specifically trained by the manufacturer.

GENERAL RECOMMENDATIONS

•  This document is an integral and essential part of the product. It is to be used by the installer and the end user, who must 

keep it carefully after the system has been installed and started.

•  The manufacturer is not liable for any damage deriving from incorrect observation of the instructions and indications 

given in this document, those relative to possible accessories supplied with the system and for the non-observance of 

pertinent applicable national and local laws.

•  Before installation and use, obtain information on the current regulations and laws in the place where the system is to be installed.
•  The SOLARSMART solar collector with integrated storage was designed and manufactured to produce domestic water that is 

heated by solar power. Any use other than that indicated relieves the manufacturer from any responsibility and renders all gua-

rantees null and void.

•  All technical drawings, plant layout and electric wiring diagrams etc. that are present in this manual are indicative and are only given 

as examples. All connections, the safety devices, diameter sizes and any other thing necessary for correct system installation must 

be verified by a qualified and expert technician, who must make sure of their correspondence with regulations and laws in force.

•  The manufacturer is not liable for any damage caused to the product resulting from assembly that is not state-of-the-art.

INDICATIONS FOR SAFETY

•  This product must be installed by a professionally qualified company or technician, according to national and/or local 

laws in force and the instructions given in this handbook.

•  Maintenance and cleaning must also be carried out by specialist companies or staff with the pertinent technical quali-

fications.

•  The term ‘professionally qualified technician’ indicates a person with specific technical skills in water for domestic use, 

as well as in heating systems, gas systems and electric systems. This person must have the professional skills indicated by law.

•  On the basis of the user guidelines, whoever uses the system must keep it in good condition and guarantee that it works safely 

and correctly.

•  The system user must ensure that the maintenance indicated in this handbook (see the Programmed maintenance chapter) is 

carried out.

•  Do not leave parts of the packaging or the system within the reach of children.

•  Before cleaning or carrying out maintenance, disconnect the power supply from any electric accessories that may be present.

•  Dispose of the various packaging elements in a suitable manner.

•  Check the pressure of the water transportation network: if the pressure is higher than the nominal pressure of the product (4 bar = 

400 kPa), prepare the necessary reduction units before the connection and regulate the pressure (see Hydraulic connection chapter)

•  Should faults occur, or if the system does not operate correctly, do not attempt to repair the product. Instead, disable it and contact 

a specialist technician. Should it be necessary, components must only be replaced with original spare parts, which must be installed 

by qualified technicians. Should this not be the case, the manufacturer reserves the right not to recognise any guarantee rights.

Содержание 3.029660

Страница 1: ...ARSMART 150R SOLARSMART 220 SOLARSMART 220R SOLARSMART 260 SOLARSMART 260R IE Instruction booklet and warning Installator User Maintenance technician IE Instruction booklet and warning Installator Use...

Страница 2: ......

Страница 3: ...the safety valve optional 20 1 13 Positioning and fixing the backflow preventer 21 1 14 Pressure reducer optional 21 1 15 Expansion vessel 22 1 16 Starting 22 1 17 Start up 23 1 18 All the uses except...

Страница 4: ...PONENT QUANTITY PIECES SOLARSMART solar collector with integrated storage 1 a b BASIC SUPPORT pair of galvanised sheet supports for flat roof 1 right 1 left c d e hammer head screw washer and nut for...

Страница 5: ...e code 3 029921 3 029922 SAFETY AND ONE WAY UNIT with MF connections Article code 3 029918 PRESSURE REDUCER with MF connections Article code 3 029919 Follow the component assembly instructions if usin...

Страница 6: ...be verified by a qualified and expert technician who must make sure of their correspondence with regulations and laws in force The manufacturer is not liable for any damage caused to the product resul...

Страница 7: ...collector PROTECTION FROM BURNS Danger The water inside the collector can reach temperatures of approximately 90 C To prevent the danger of burns and or scalds be extremely careful when connecting th...

Страница 8: ...anner Perforate with drill READ AND UNDERSTAND THE INSTRUCTIONS Read and understand the appliance s instructions before performing any operation carefully following the indications provided INFORMATIO...

Страница 9: ...protective helmet must be worn PPE must be used when working at heights Protective goggles must be worn PERSONAL PROTECTIVE EQUIPMENT DANGER Generic danger Risk of falling from a height Risk of burns...

Страница 10: ...of a suitable capacity and size 1 2 STRUCTURAL CHECK The SOLARSMART solar collector with integrated storage can be placed on the ground or on a structure attic covering balcony etc that can support t...

Страница 11: ...standards in force The usual PPE must be worn for all in stallation operations drilling moving etc Risk of electric shock Only work near overhanging power cables where contact is possible if the powe...

Страница 12: ...mendments 1 6 HARDNESS It is recommended to use water with a hardness of between 10 F and 30 F In the case of water with a greater hardness than 30 F it is recommended to carry out a softening treatme...

Страница 13: ...long as possible Nearby obstacles trees buildings etc can temporarily shade the system and reduce even greatly its performance If positioning several collectors behind each other do not let them shad...

Страница 14: ...14 4c 4b 4 4a 3c 3d 3a 3b A 1a 1c 1b A 3 1 2 4 INSTALLER USER MAINTENANCE TECHNICIAN INSTALLATION PHASES FLAT ROOF 13 Max 20 Nm SNOW LOAD WIND LOAD 1 2 kN m2 100 Km h...

Страница 15: ...15 4g 4f 4d 4e 7 5 8 6 5a 5d 5c 5b 5a 5b 5c 5d A 6a A B 7b 7a 7a 7b 8b 8b 8a A SOLARSMART A B 110 150 2050 150 250 2050 220 500 2050 260 600 2050 INSTALLER USER MAINTENANCE TECHNICIAN...

Страница 16: ...PLACE AND POSITION Carefully check the state of the cover and the suppor ting structure Get a structural technician to check the maximum loads of the building considering the weight of the system when...

Страница 17: ...17 7c 7b 7 7a 3 1 2 4 A 5 25 cm 5 25 cm INSTALLER USER MAINTENANCE TECHNICIAN INSTALLATION PHASE SLOPED ROOF SNOW LOAD WIND LOAD 1 2 kN m2 100 Km h...

Страница 18: ...18 7h 7g 7d 7e 7f 5 6 7 8 9 A A 13 13 INSTALLER USER MAINTENANCE TECHNICIAN...

Страница 19: ...connection tighten the other connection using the torque wrench without exceeding a tightening torque of 20 Nm Using flexible hoses 1 10 USING FLEXIBLE HOSES Only removable connections e g stainless...

Страница 20: ...LTERNATIVE TO THE SAFETY VALVE OPTIONAL ForinstallationsinItalyandincountrieswherearegulationsimilar to the one established by Ministerial Circular no 829571 of 26 March 2003 regarding accumulation wa...

Страница 21: ...rned perfectly upwards in other words it must create a 90 angle as to the hori zontal surface 12 Before tightening the valve to the outflow connection connect between the valve and the user supply lin...

Страница 22: ...grated solar collector is supplied with a plasticizer free PVC covering sheet which serves the purpose of blacking out the surface that captures the solar irradiation This will prevent the product fro...

Страница 23: ...nd even damage the collector itself Allow the water to flow inside the system for a certain period of time in order to rinse out any deposits or residues that could have entered the tank during instal...

Страница 24: ...ust be installed in the upper part of the solar collector opposite the side where the outflow connection is positioned M The antifreeze resistor L da 0 3 kW must be installed in the lower part of the...

Страница 25: ...directly to the user without the addition of a boiler downstream In periods of less irradiation and colder months the 1 and 2 kW electric resistances serve as heat integration in order to bring the wa...

Страница 26: ...high performing stainless steel cylinders 4 made of a special alloy that resists high pressures and also very corrosive water The cylinders are closed at their ends by special caps 5 made of thermopla...

Страница 27: ...a period of up to 30 days it is possible to leave the plant filled with water and the solar collector uncovered Nevertheless before reusing the hot water it is a good idea to completely empty the tan...

Страница 28: ...alve with serious consequencesfortheintegrityoftheaccumulationtank In this case it will be necessary to installasofteningorfiltrationdeviceupstreamfromthesystem carryoutadequatecleaningandifnecessary...

Страница 29: ...d The connection drawing that is represented just like those on the following pages is purely indicative and only indicates how to connect the hydraulic connections and install the main supplied compo...

Страница 30: ...on is the responsibility of the installer he she has the task of verifying if what is indicated in this manual complies with laws and re gulations in force at the installation place The manufacturer i...

Страница 31: ...m 31 max 3BAR 3 6 CONNECTING MORE THAN ONE COLLECTOR If it is necessary to use several collectors parallel connection is strongly recommended The parallel connection must be made in a balanced manner...

Страница 32: ...0mm 2050mm Gross surface area 1 52 m2 1 93 m2 2 77 m2 3 18 m2 Surface area when open 1 09 m2 1 48 m2 2 25 m2 2 64 m2 Absorption surface area 0 85 m2 1 13 m2 1 69 m2 1 98 m2 Effective ACS content 105 l...

Страница 33: ...33...

Страница 34: ...34...

Страница 35: ...35...

Страница 36: ...Cod 1 0435191ENG rev ST 004221 002 02 22 This instruction booklet is made of ecological paper immergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617...

Отзывы: