DMX LED Spotlight
These instructions are intended for installers of the
unit and for users with basic knowledge in DMX
control . Please read the instructions carefully prior to
operation and keep them for later reference .
All operating elements and connections de-
scribed can be found on the page 2 .
1 Overview
1
XLR chassis plug DMX INPUT: DMX signal input
for connecting a light controller or the DMX signal
output of another spotlight
2
Clip to secure the barn doors
3
XLR jack DMX OUTPUT: DMX signal output for
connecting the DMX input of another DMX-con-
trolled unit
4
Mains cable for connection to a socket (230 V/ 50 Hz)
5
Locking screws for the mounting brackets
6
Mounting brackets / stand
7
Buttons to select the operating mode and to
change settings via the menu
8
Display
2 Safety Notes
The spotlight corresponds to all relevant directives of
the EU and is therefore marked with .
WARNING
The spotlight uses dangerous mains
voltage . Leave servicing to skilled per-
sonnel and do not insert anything into
the air vents; inexpert handling may
result in electric shock .
•
The spotlight is suitable for indoor use only . Protect
it against dripping water, splash water and high
air humidity . The admissible temperature range
is 0 – 40 °C .
•
Do not operate the spotlight or immediately dis-
connect the mains plug from the socket
1 . if the spotlight or the mains cable is visibly
damaged,
2 . if a defect might have occurred after a unit was
dropped or suffered a similar accident,
3 . if malfunctions occur .
In any case the spotlight must be repaired by skilled
personnel .
•
A damaged mains cable must be replaced by
skilled personnel only .
•
Never pull the mains cable to disconnect the mains
plug from the socket, always seize the plug .
•
No guarantee claims for the spotlight and no lia-
bility for any resulting personal damage or material
damage will be accepted if the spotlight is used
for other purposes than originally intended, if it is
not safely installed or not correctly connected or
operated, or if it is not repaired in an expert way .
•
Important for U. K. Customers!
The wires in this mains lead are coloured in
ac cord ance with the following code:
green / yellow = earth
blue = neutral
brown = live
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
1 . The wire which is coloured green and yellow
must be connected to the terminal in the plug
which is marked with the letter E or by the
earth symbol , or coloured green or green
and yellow .
2 . The wire which is coloured blue must be con-
nected to the terminal which is marked with
the letter N or coloured black .
3 . The wire which is coloured brown must be con-
nected to the terminal which is marked with the
letter L or coloured red .
Warning – This appliance must be earthed.
If the spotlight is to be put out of operation
definitively, take it to a local recycling plant
for a disposal which is not harmful to the
environment .
3 Applications
This LED spotlight is used for illumination, e . g . on
stage, in discotheques and function rooms . The
light source is a high-power RGB COB LED (COB =
chip-on-board technology): Many individual LEDs in
the colours red, green and blue are mounted close
together on a chip, thus providing a uniform light
distribution . The spotlight is designed for control via
a DMX light controller (3, 4, 5 or 10 DMX control
channels), but it can also be operated independently
without a controller .
As a special feature, the spotlight supports 66
subaddresses for DMX operation . Thus, it is pos-
sible to independently control up to 66 spotlights
(spotlight groups) via a single DMX start address
and the maximum number of DMX units that can
be controlled is substantially increased .
4 Setting the Spotlight into
Operation
4.1 Installation
•
Always position the spotlight in such a way that
sufficient air circulation is ensured during oper-
ation . Never cover the air vents of the housing .