21
2.6 Handcontrol Mode
When the
AUTOMATIC reflow process is running
you can go over from automatic mode in to hand control
mode.
By pushing the
green button
the machine will go automatically in the cooling modus and the blowers will switch
on and will cool down the machine.
IF you press the
red button
the the machine will be switching over in the lineair reflow solder mode and switch
off to cooldown at 230 C degrees or 220, 210, 230 degrees depending which value was stored in EEPROM.
4.0 Overheat protection
During the relflow modus the machine is continually sensing the Galden Temperature and
automatically switch of de heaters and starting the cool down if the Galden temperature exceeds its
limits
ANTI TOMBSTONE REFLOWING PROFILER WITH
CVPRS
Creative Vapor Phase Reflow Software
2.3 Maintenance
Soldering, as everyone knows, is a quit "dirty" process due Flux residue and other materials.
Residues, which are sometimes very sticky, get into the air or because they are in the
DINO-CONDENS-
IT
,
barely can escape - are deposited on all parts with which they come into contact and also mix with the GALDEN.
2.4 Tips from practice:
If you wait too long with cleaning, it becomes very difficult to remove the deposits. Therefore more frequent
cleaning will mean more ease in removing this pollutant, specifically on the bottom of the process chamber the
contour of the heater coil can be seen.