The strands should be soldered as flat as possible to the copper band. Sensor cables and
connection cables should not cross. Wrap the secondary coil with 3 layers of heat-
resistant adhesive tape to prevent overheating.
For measurements on high speed or high temperature shafts, CAEMAX offers special
solutions (half shells, special casings, etc.)
For further questions and instructions concerning your individual situation, please contact
CAEMAX support.
9. Apply secondary layer of heat resistant tape.
10.
Now connect the SCT to the secondary coil (see connecting diagram in section 2.2).
Therefore, use the connections designated for inductive power supply.
Figure 42: cross-section of secondary coil for inductive power supply