5.4.2 Technical Data
Dimensions
ca. 84x54x37mm w/o copper wire
Diameter of copper wire
ca. 8mm
Weight
ca. 324 g w/o copper wire
Temperature range
-
10°C … +85°C
Transmission distance
0 … 70 mm
Diameter of primary coil
30 … 1000 mm
Ratio secondary/primary coil
> 1: 3
Power consumption
max. 20 W
Efficiency
< 0.1
Transmission frequency
30 ... 60 kHz, automatically controlled
Supply voltage
9 … 36 V/DC
Protection class
IP 67
Connecting cable
Lemo plug, banana plugs, length 5m
Connectors
Lemo
5.4.3 Installation and Placing into Operation
Mount the ring stator electronics at an arbitrary place next to the axle shaft.
Please note:
Temperature rise of the stator electronics above 80°C may lead to
damage or even breakdown of the stator. To avoid that, provide sufficient heat
dissipation, e.g. by installing the stator on a metallic surface.