3.6.4 Configure Full Bridges / Half Bridges
Make sure the desired channel has been assigned the correct signal mode
(see section 3.6.1).
Open the desired channel by selecting
Channels→Channel X.
3.6.4.1 Calibration
In the
Calibration
section, enter a two-point calibration line in the fields
Sample 1
and
Sample 2.
Define physical unit of output in the
Units
field.
When configuring with a web browser, confirm your input with the
Set
button to resume it to
the D
X
.
3.6.4.2 Autozero
Check the
Autozero
box to select the channel for zero adjustment in measuring mode.
When configuring with a web browser, confirm your input with the
Set
button to resume it to
the D
X
.
Please note:
Zero adjustment is permanently stored in the D
X
and is reloaded when the
system is restarted.
3.6.4.3 Measurement Range
Enter upper and lower bound of desired measurement range in the fields
Range min:
and
Range max.
The measurement range resolution is 16 bits.
Please note:
The measurement range can be increased/decreased by powers of two and is
centered on zero.
When configuring with a web browser, confirm your input with the
Set
button to resume it to
the D
X
.
Select
Program
.
Please note:
Make sure the SCT is switched on (i.e. supplied with power) and radio
transmission from RCI to SCT is undisturbed. Otherwise, the SCT can’t be programmed
successfully.
Confirm the message
.
Содержание CAEMAX DX
Страница 31: ...Dx Telemetry System Manual Vers 2 7 31 92 Figure 20 Strain gauge channel configuration...
Страница 44: ...Dx Telemetry System Manual Vers 2 7 44 92 Menu tree continued...
Страница 84: ...Dx Telemetry System Manual Vers 2 7 84 92 10 Questions Answers 10 1 Inductive Power Supply Troubleshooting...
Страница 85: ...Dx Telemetry System Manual Vers 2 7 85 92...
Страница 86: ...Dx Telemetry System Manual Vers 2 7 86 92...