NEXIO AMP
Hardware Installation and User Guide
19
Rear Panel Port
Descriptions
The following sections describe the NEXIO AMP rear panel port connections.
SYS ID
The SYS ID button enables you to identify a server from the front. When you press the SYS
ID button, the front panel indicator illuminates so that you can easily identify the applicable
server.
Power Supply Alarm Reset
The power supply alarm reset button silences the power supply alarm.
Power Supplies
NEXIO AMP has two redundant hot swappable power supplies located on the back panel.
Under normal operation both power supplies work in tandem spreading the load between
them. In the event of a failure, the functional power supply provides all power needed by
NEXIO AMP.
To identify and remove the failed power supply
1
Look at the status LED on the front of each power supply. The LED on the failed power supply will
not be illuminated.
Figure 2-3
-------------Power Supply Module
2
To remove a power supply, push the release tab to the left.
3
Hold the release tab to the left, grasp the power supply handle, and pull the power supply out of the
frame.
To insert a new power supply
1
Slide the replacement power supply into the empty slot.
2
Press firmly so that it clicks in place. If the power supply cord is in place, the module's status LED will
illuminate.
Release
Tab
Handle
Status