NEXIO AMP
Hardware Installation and User Guide
13
Storage
The following table describes NEXIO AMP storage specifications.
RAID Redundancy
The following table describes the NEXIO AMP RAID redundancy specifications.
Timecode
Connection Options
The following list describes the timecode connections options for NEXIO AMP.
RS-232
TCP/IP
Leitch clock interface
VITC reader, writer, and generator
Remote GPI Control
The following table describes the GPI control specifications for NEXIO AMP.
Remote Serial
Interface
The following list describes the remote serial interface specifications for NEXIO AMP:
RS-422 ports for control of up to eight channels; one port can be allocated for a VTR
RJ-12 connector
Harris ADC VDCP pinout (see
NEXIO AMP RS-422 Pinouts
on page 46)
Table 1-8
Storage Specifications
Storage
8x internal SATA-2 hot-swappable drives (standard);
additional 8x internal SATA-2 hot-swappable drives
(available for purchase)
Table 1-9
RAID Redundancy Specifications
Controller
RAIDsoft™ software RAID management
system
RAID Protection Schemes
Per Volume
RAID 3 (single drive parity; single drive
failure protection)
-OR-
ECC (multiple drive parity; dual drive
failure protection)
Table 1-10
GPI Control Specifications for NEXIO AMP
Inputs
32 inputs (two 26-pin MDR connectors)
Outputs
16 outputs (two 26-pin MDR connectors)
Содержание Nexio AMP NX3601 HDX
Страница 54: ...Chapter 6 Troubleshooting 54...