Dseries Harris J/S (JSC-2) Jog-Shuttle Control Panel  
Reference 

 

Operation 

 

Button    
Description 

Previous 
Keycap 
Engraving 

DALstation Functionality 

Fifth Button, 
Third Row

 

 

If one of the following contexts is applicable, ‘Stop’ 
is commanded. 

1.  Ad Hoc Ingest Window is open (Source or 

Destination assigned) 

2.  Record bus is displayed (Destination 

assigned) 

3.  VCP Window is active (Source assigned) 

Reconfigurable

? No. 

Second 
(CW) Button 
Surrounding 
Knob 

MARK 
SOM 

1.  Copy current timecode from destination 

machine into on-air event’s bus SOM field 
with Ad Hoc Ingest Window open (Destination 
assigned) or Record bus displayed 
(Destination assigned). In addition, 

 

If the ‘Use first bus item’ is set to ‘Y’ in 
BUS.TBL, the SOM of the item for each 
bus machine will be set to the current 
timecode of the assigned destination 
machine,  

 

If the ‘Use first bus item’ field in BUS.TBL 
is either blank or set to ‘N’, the SOM of 
the item for only the assigned destination 
machine will be set to the current 
timecode reported by that bus or bus 
monitor machine. Since all other 
machines are unaffected, the Mark SOM 
command needs to be performed once for 
each bus machine. 

2.  If the Ad Hoc Ingest Window is active (Source 

Assigned) and the source assignment is from 
the schedule, the SOM of the source machine 
is written to the sub-event field.  

3.  If the VCP Window is active (Source 

Assigned) and displays a valid timecode, the 
current timecode is copied from the VCP 
Window timecode display to the VCP Window 
SOM field (Note: Bus display does not reflect 
SOM change until ‘Set Event Data’ button is 
selected from VCP Window). 

* See additional note following this table. 

Reconfigurable

? No. 

Third (CW) 
Button 
Surrounding 
Knob 

GO TO 
SOM 

If one of the following contexts is applicable, ‘Go 
to Start of Material’ is commanded. 

1.  Ad Hoc Ingest Window is open (Source or 

Destination assigned)  

2.  Record bus is displayed (Destination 

assigned) 

3.  VCP Window is active (Source assigned) 

Reconfigurable

? No. 

 

© 2014 Imagine Communications Corp.     Proprietary and Confidential 

 9-April-2014  | Page 13 of 21 

Содержание 502072-00

Страница 1: ...Reference D Series Harris J S JSC 2 Jog Shuttle Panel Reference 11 April 2011...

Страница 2: ...magine Communications reserves the right without notice to make such changes in equipment design specifications components or documentation as progress may warrant to improve the performance of the pr...

Страница 3: ...imecode Display 10 Jog Shuttle Wheel 10 Direction Indicator 10 Button Mapping 11 DALstation Functionality 11 DALingest Functionality 14 Troubleshooting 17 Loss of JSC 2 Comms 17 Configuration 18 DALst...

Страница 4: ......

Страница 5: ...articles immediately upon receipt Any damage discovered should be cause for a damage claim against the carrier WEEE and RoHS Compliance Panels addressed in this document are WEEE and RoHS Compliant T...

Страница 6: ...l of waste electrical and electronic equipment WEEE on the manufacturers of such equipment The companies are compelled to use the collected waste in an ecological friendly manner either by ecological...

Страница 7: ...nsport button control in addition to an automation s Device Control Interface and a broadcast device s conventional transport controls When used in conjunction with an automation playout or ingest wor...

Страница 8: ...ns for a JSC 2 Panel Specification Description Size 10 5 x 6 5 x 3 5 26 7 x 16 5 x 8 9 Weight 4 lbs 1 8 KG Power Requirements The JSC 2 comes with an external power supply brick universal 12 volt DC s...

Страница 9: ...ned on both Button mapping for the JSC 2 panel is shown by the following diagram About Lamp States Buttons with a Lamp state Buttons dependent on showing a lamp state for proper User Interface operati...

Страница 10: ...nsport status Stop Pause Play Forward Reverse Note Firmware version v2 14 or higher is required to use the Timecode display Firmware versions prior to v2 14 do not support jog shuttle querying and the...

Страница 11: ...Shuttle Panel always controls the assigned bus machine for record buses while the Ad Hoc Ingest Window is not open Reconfigurable No First Button Second Row HOLD If a recording is in progress the cou...

Страница 12: ...tton Third Row If one of the following contexts is applicable Play is commanded 1 Ad Hoc Ingest Window is open Source or Destination assigned 2 Record bus is displayed Destination assigned 3 VCP Windo...

Страница 13: ...ssigned destination machine will be set to the current timecode reported by that bus or bus monitor machine Since all other machines are unaffected the Mark SOM command needs to be performed once for...

Страница 14: ...ported by the destination machine and its SOM possibly set previously 2 If the Ad Hoc Ingest Window is active Source Assigned and the source assignment is from the schedule the calculated Duration is...

Страница 15: ...segment is added to the loaded material Reconfigurable No Sixth Button Second Row OK If the Ingest Review Window is displayed and is waiting for acknowledgement acceptance or rejection of recording i...

Страница 16: ...xt If a highlighted segment exists for the loaded material the segment SOM is set to the displayed timecode in the Device Control Area The segment s Duration and EOM are updated according to the curre...

Страница 17: ...one of the following functions is invoked followed by updating the material duration according to the current context If a highlighted segment exists for the loaded material the segment EOM is set to...

Страница 18: ...by the operator Configurations of other panels connected via serial connection e g the DAL Jog Shuttle Control Panel are stored across sessions in the DALingest INI file Cabling Pinouts A single JSC 2...

Страница 19: ...Pin 3 RX Pin 2 TX Pin 8 RX Pin 3 RX Pin 7 TX Pin 4 GND Pin 1 GND Pin 6 RX Pin 2 TX USB to RS422 lead converter DB9F to DB9F The following USB to RS422 lead converter DB9F to DB9F pinouts are tested a...

Страница 20: ...ations is not liable for any special indirect or consequential damages however caused To Return a Unit Follow this procedure when returning a defective unit for replacement Stage Action 1 Contact your...

Страница 21: ...t Contact your Automation representative to order D Series Hardware components When ordering specify the components by Product Code Device Type Model Part Number Jog Shuttle Controller with Timecode D...

Отзывы: