background image

Dseries Harris J/S (JSC-2) Jog-Shuttle Control Panel  
Reference 

 

Unit Replacement 

 

Unit Replacement 

Notice to the Original Purchaser 

If this unit fails under normal use, and the unit is within the Standard Warranty period 
and/or is covered under a valid Support Contract with Imagine Communications, and 
Imagine Communications determines - in its sole discretion - that the product is 
defective, and provided that the purchaser returns the product, properly packaged 
and freight prepaid to Imagine Communications, Imagine Communications will - at its 
option - repair or replace the product. 

No warranty is implied or expressed as to the suitability of this product for a particular 
usage and Imagine Communications is not liable for any special, indirect, or 
consequential damages, however caused. 

To Return a Unit 

Follow this procedure when returning a defective unit for replacement. 

Stage 

Action 

Contact your Imagine Communications Representative to report the 
problem. 

Get an RMA number (Return Materials Authorization) for the unit from 
Imagine Communications. 

Request the proper “ship to” address:  

The Americas 

Europe, Asia, Africa 

Imagine Communications 

Automation  

9800 S. Meridian Blvd 

Englewood, CO  80112  USA 

Ph +1 303 476 5000 

Imagine Communications  

Automation 

Eskdale Road 

Winnersh Triangle 

Reading, Berkshire 

England  RG41 5TS 

Ph +44   (0) 118 9648189 

 

Repackage the unit and Ship To: the Imagine Communications office 
designated in stage 3. 

Imagine Communications will, at its option, repair or replace the product. 

 

© 2014 Imagine Communications Corp.     Proprietary and Confidential 

 9-April-2014  | Page 20 of 21 

Содержание 502072-00

Страница 1: ...Reference D Series Harris J S JSC 2 Jog Shuttle Panel Reference 11 April 2011...

Страница 2: ...magine Communications reserves the right without notice to make such changes in equipment design specifications components or documentation as progress may warrant to improve the performance of the pr...

Страница 3: ...imecode Display 10 Jog Shuttle Wheel 10 Direction Indicator 10 Button Mapping 11 DALstation Functionality 11 DALingest Functionality 14 Troubleshooting 17 Loss of JSC 2 Comms 17 Configuration 18 DALst...

Страница 4: ......

Страница 5: ...articles immediately upon receipt Any damage discovered should be cause for a damage claim against the carrier WEEE and RoHS Compliance Panels addressed in this document are WEEE and RoHS Compliant T...

Страница 6: ...l of waste electrical and electronic equipment WEEE on the manufacturers of such equipment The companies are compelled to use the collected waste in an ecological friendly manner either by ecological...

Страница 7: ...nsport button control in addition to an automation s Device Control Interface and a broadcast device s conventional transport controls When used in conjunction with an automation playout or ingest wor...

Страница 8: ...ns for a JSC 2 Panel Specification Description Size 10 5 x 6 5 x 3 5 26 7 x 16 5 x 8 9 Weight 4 lbs 1 8 KG Power Requirements The JSC 2 comes with an external power supply brick universal 12 volt DC s...

Страница 9: ...ned on both Button mapping for the JSC 2 panel is shown by the following diagram About Lamp States Buttons with a Lamp state Buttons dependent on showing a lamp state for proper User Interface operati...

Страница 10: ...nsport status Stop Pause Play Forward Reverse Note Firmware version v2 14 or higher is required to use the Timecode display Firmware versions prior to v2 14 do not support jog shuttle querying and the...

Страница 11: ...Shuttle Panel always controls the assigned bus machine for record buses while the Ad Hoc Ingest Window is not open Reconfigurable No First Button Second Row HOLD If a recording is in progress the cou...

Страница 12: ...tton Third Row If one of the following contexts is applicable Play is commanded 1 Ad Hoc Ingest Window is open Source or Destination assigned 2 Record bus is displayed Destination assigned 3 VCP Windo...

Страница 13: ...ssigned destination machine will be set to the current timecode reported by that bus or bus monitor machine Since all other machines are unaffected the Mark SOM command needs to be performed once for...

Страница 14: ...ported by the destination machine and its SOM possibly set previously 2 If the Ad Hoc Ingest Window is active Source Assigned and the source assignment is from the schedule the calculated Duration is...

Страница 15: ...segment is added to the loaded material Reconfigurable No Sixth Button Second Row OK If the Ingest Review Window is displayed and is waiting for acknowledgement acceptance or rejection of recording i...

Страница 16: ...xt If a highlighted segment exists for the loaded material the segment SOM is set to the displayed timecode in the Device Control Area The segment s Duration and EOM are updated according to the curre...

Страница 17: ...one of the following functions is invoked followed by updating the material duration according to the current context If a highlighted segment exists for the loaded material the segment EOM is set to...

Страница 18: ...by the operator Configurations of other panels connected via serial connection e g the DAL Jog Shuttle Control Panel are stored across sessions in the DALingest INI file Cabling Pinouts A single JSC 2...

Страница 19: ...Pin 3 RX Pin 2 TX Pin 8 RX Pin 3 RX Pin 7 TX Pin 4 GND Pin 1 GND Pin 6 RX Pin 2 TX USB to RS422 lead converter DB9F to DB9F The following USB to RS422 lead converter DB9F to DB9F pinouts are tested a...

Страница 20: ...ations is not liable for any special indirect or consequential damages however caused To Return a Unit Follow this procedure when returning a defective unit for replacement Stage Action 1 Contact your...

Страница 21: ...t Contact your Automation representative to order D Series Hardware components When ordering specify the components by Product Code Device Type Model Part Number Jog Shuttle Controller with Timecode D...

Отзывы: