background image

Dseries Harris J/S (JSC-2) Jog-Shuttle Control Panel  
Reference 

 

Operation 

 

 

The Jog sensitivity of the JSC-2 panel is approximately 3 frames per full 
revolution- to be in line with other D-Series panels. 

Button Mapping 

The following tables outline button mapping and functionality for the JSC-2 when 
used wit

DALstation

 or when used wit

DALingest

 

DALstation Functionality 

Button    
Description 

Previous 
Keycap 
Engraving 

DALstation Functionality 

Leftmost 
Button, Top 
Row 

SOURCE 

If either the Ad Hoc Ingest Window is open with 
the DEST button lit on the panel, or the VCP 
Window is active with the SOURCE button lit, 
control of the source machine for the cursor 
event’s main source or on-air source for the bus is 
provided. 

Reconfigurable

? No. 

Rightmost 
Button, Top 
Row 

DEST 

When the Ad Hoc Ingest Window is open, control 
of the record bus monitoring machine for the 
current bus is provided. In addition, the 
Jog/Shuttle Panel always controls the assigned 
bus machine for record buses while the Ad Hoc 
Ingest Window is not open 

Reconfigurable

? No. 

First Button, 
Second Row 

HOLD 

If a recording is in progress, the countdown on the 
current recording is paused (effectively extending 
the on-air event’s duration)  

Reconfigurable

? Yes. 

Second 
Button, 
Second Row 

TAKE 

If the next event is scheduled, start the next 
recording. 

Reconfigurable

? Yes. 

Third 
Button, 
Second Row 

END 

If a recording is in progress, prematurely end the 
current recording. 

Reconfigurable

? Yes. 

Fourth 
Button, 
Second Row 

DELETE 

While waiting for confirmation or 
acknowledgement with the VCP Window inactive, 
rejection of a completed recording is initiated 
(“OK” acknowledgement required to complete 
deletion) or the “Reject Recording” dialog box is 
cancelled 

Reconfigurable

? No. 

Fifth Button, 
Second Row 

ACCEPT 

While waiting for confirmation or 
acknowledgement with the VCP Window inactive, 
acceptance of a completed recording is initiated 
(“OK” acknowledgement required to complete 

 

© 2014 Imagine Communications Corp.     Proprietary and Confidential 

 9-April-2014  | Page 11 of 21 

Содержание 502072-00

Страница 1: ...Reference D Series Harris J S JSC 2 Jog Shuttle Panel Reference 11 April 2011...

Страница 2: ...magine Communications reserves the right without notice to make such changes in equipment design specifications components or documentation as progress may warrant to improve the performance of the pr...

Страница 3: ...imecode Display 10 Jog Shuttle Wheel 10 Direction Indicator 10 Button Mapping 11 DALstation Functionality 11 DALingest Functionality 14 Troubleshooting 17 Loss of JSC 2 Comms 17 Configuration 18 DALst...

Страница 4: ......

Страница 5: ...articles immediately upon receipt Any damage discovered should be cause for a damage claim against the carrier WEEE and RoHS Compliance Panels addressed in this document are WEEE and RoHS Compliant T...

Страница 6: ...l of waste electrical and electronic equipment WEEE on the manufacturers of such equipment The companies are compelled to use the collected waste in an ecological friendly manner either by ecological...

Страница 7: ...nsport button control in addition to an automation s Device Control Interface and a broadcast device s conventional transport controls When used in conjunction with an automation playout or ingest wor...

Страница 8: ...ns for a JSC 2 Panel Specification Description Size 10 5 x 6 5 x 3 5 26 7 x 16 5 x 8 9 Weight 4 lbs 1 8 KG Power Requirements The JSC 2 comes with an external power supply brick universal 12 volt DC s...

Страница 9: ...ned on both Button mapping for the JSC 2 panel is shown by the following diagram About Lamp States Buttons with a Lamp state Buttons dependent on showing a lamp state for proper User Interface operati...

Страница 10: ...nsport status Stop Pause Play Forward Reverse Note Firmware version v2 14 or higher is required to use the Timecode display Firmware versions prior to v2 14 do not support jog shuttle querying and the...

Страница 11: ...Shuttle Panel always controls the assigned bus machine for record buses while the Ad Hoc Ingest Window is not open Reconfigurable No First Button Second Row HOLD If a recording is in progress the cou...

Страница 12: ...tton Third Row If one of the following contexts is applicable Play is commanded 1 Ad Hoc Ingest Window is open Source or Destination assigned 2 Record bus is displayed Destination assigned 3 VCP Windo...

Страница 13: ...ssigned destination machine will be set to the current timecode reported by that bus or bus monitor machine Since all other machines are unaffected the Mark SOM command needs to be performed once for...

Страница 14: ...ported by the destination machine and its SOM possibly set previously 2 If the Ad Hoc Ingest Window is active Source Assigned and the source assignment is from the schedule the calculated Duration is...

Страница 15: ...segment is added to the loaded material Reconfigurable No Sixth Button Second Row OK If the Ingest Review Window is displayed and is waiting for acknowledgement acceptance or rejection of recording i...

Страница 16: ...xt If a highlighted segment exists for the loaded material the segment SOM is set to the displayed timecode in the Device Control Area The segment s Duration and EOM are updated according to the curre...

Страница 17: ...one of the following functions is invoked followed by updating the material duration according to the current context If a highlighted segment exists for the loaded material the segment EOM is set to...

Страница 18: ...by the operator Configurations of other panels connected via serial connection e g the DAL Jog Shuttle Control Panel are stored across sessions in the DALingest INI file Cabling Pinouts A single JSC 2...

Страница 19: ...Pin 3 RX Pin 2 TX Pin 8 RX Pin 3 RX Pin 7 TX Pin 4 GND Pin 1 GND Pin 6 RX Pin 2 TX USB to RS422 lead converter DB9F to DB9F The following USB to RS422 lead converter DB9F to DB9F pinouts are tested a...

Страница 20: ...ations is not liable for any special indirect or consequential damages however caused To Return a Unit Follow this procedure when returning a defective unit for replacement Stage Action 1 Contact your...

Страница 21: ...t Contact your Automation representative to order D Series Hardware components When ordering specify the components by Product Code Device Type Model Part Number Jog Shuttle Controller with Timecode D...

Отзывы: