Dseries Harris J/S (JSC-2) Jog-Shuttle Control Panel
Reference
Operation
Button
Description
Previous
Keycap
Engraving
DALingest Functionality
Fifth (CW)
Button
Surrounding
Knob
GO TO
EOM
1. If the Ingest Review Dialog is active, move to
the EOM of the ingested clip
2. If the Ingest Review Dialog is inactive, one of
the following functions is invoked,
Move to the EOM of the loaded material, if
segments and events do not exist or
neither is highlighted,
Move to the EOM of the highlighted
segment, if a segment is highlighted
Move to the EOM of the highlighted event,
if an event is highlighted
Reconfigurable
? No.
Sixth (CW)
Button
Surrounding
Knob
MARK
EOM
1. If the Ingest Review Dialog is active, the
ingested clip’s EOM is set to the timecode
displayed in the Ingest Review Dialog.
2. If the Ingest Review Dialog is not active, one of
the following functions is invoked followed by
updating the material duration, according to the
current context,
If a highlighted segment exists for the
loaded material, the segment EOM is set
to the displayed timecode in the Device
Control Area. The segment’s Duration is
updated according to the current context.
If a highlighted event exists for the loaded
material, the event EOM is set to the
displayed timecode in the Device Control
Area. The event’s Duration is updated
according to the current context.
If segments and events do not exist or
neither is highlighted, the material’s EOM
is set to the displayed timecode in the
Device Control Area.
Reconfigurable
? No.
Troubleshooting
Loss of JSC-2 Comms
The JSC-2 panel will occasionally fail to respond to the Jog/Shuttle Query message,
causing a ‘bad comm’. However, any action taken by the panel (such as a button
press or jog wheel movement) will re-establish the comm. state.
© 2014 Imagine Communications Corp. Proprietary and Confidential
9-April-2014 | Page 17 of 21
Содержание 502072-00
Страница 1: ...Reference D Series Harris J S JSC 2 Jog Shuttle Panel Reference 11 April 2011...
Страница 4: ......