Command Line Interface (CLI)
33
Return parameters
Return value Description
0
digital input „Camera Trigger“ is not activated
1
digital input „Camera Trigger“ is activated
Table 2
6.2.12 Get Stop Trigger Input State
Function
getStopTrigger
Description
“LED-Panel.exe -getStopTrigger” returns the state of the digital input “Stop Trigger”.
Return parameters
Return value
Description
0
digital input „Stop Trigger“ is not activated
1
digital input „Stop Trigger“ is activated
Table 3
6.2.13 Get the Number of Currently Activated LED
Function
getCurrentLED
Description
With the function
“LED-Panel.exe -getCurrentLED” it is possible to read which LED is currently
turned on, respectively
the number of switching periods occurred after activating the „Camera
Trigger“ input.
Return parameters
After the execution of the command
“LED-Panel.exe -getCurrentLED” the device will return a
two- or three-digits value of the currently switched LED like XYY or YY. Where X is a one-digit
value of the lighted LED of the lower LED row and YY is two-digit value of the lighted LED in the
10x10 LED array.