Command Line Interface (CLI)
39
Return values
After the execution of this function the device will return a one-digit value of the current direction
of the LED columns. For the list of the possible return values please refer to the Table 2.
6.2.25 Set LEDs switching t
ime for the “Exposure Time” mode
Function
setTime <XX>
Description
With the function
“
LED-Panel.exe -setTime <XX>
“ it is possible to set the switching time of the
LEDs
in the “Exposure Time” mode.
Parameters
To set the desired switching time between 1/5000s and 10s please refer to the following table.
PLEASE NOTE
Parameters 01 to 14 are currently not applicable. They are reserved for future design.
<XX>
switching
time [s]
<XX>
switching
time [s]
<XX>
switching
time [s]
<XX>
switching
time [s]
01
1/100000
20
1/2000
39
1/100
58
0.4s
02
1/80000
21
1/1600
40
1/80
59
0.5s
03
1/64000
22
1/1500
41
1/64
60
0.6s
04
1/50000
23
1/1300
42
1/60
61
0.8s
05
1/40000
24
1/1250
43
1/50
62
1s
06
1/32000
25
1/1000
44
1/40
63
1.25s
07
1/25000
26
1/800
45
1/32
64
1.3s
08
1/20000
27
1/640
46
1/30
65
1.5s
09
1/16000
28
1/600
47
1/25
66
1.6s
10
1/12500
29
1/500
48
1/20
67
2s
11
1/10000
30
1/400
49
1/16
68
2.5s
12
1/8000
31
1/320
50
1/15
69
3s
13
1/6400
32
1/300
51
1/13
70
3.2s
14
1/6000
33
1/250
52
1/10
71
4s
15
1/5000
34
1/200
53
1/8
72
5s
16
1/4000
35
1/160
54
1/6
73
6s
17
1/3200
36
1/150
55
1/5
74
6.4s
18
1/3000
37
1/130
56
1/4
75
8s
19
1/2500
38
1/125
57
0.3s
76
10s
Table 10