- 25 -
S-2018
REV. D
•
The pictures below illustrate how to incorrectly and correctly cinch the drawstring cord.
•
Tuck the inner skirt under your protective clothing and allow the outer skirt to hang outside.
•
With the respirator in operation and donned according to the instructions, enter the contaminated area,
breathing normally. Keep all the respirator system’s components away from equipment, vehicles and
other physical and chemical hazards.
•
Once the hood is installed, ensure that the head harness is properly fitted by turning your head side-to-
side to verify that the head harness is secure and does not slip on the forehead. If slipping occurs,
remove the hood and adjust the head harness to a smaller size.
∆
WARNING
DO NOT REMOVE RESPIRATOR SYSTEM WHILE YOU ARE IN A HAZARDOUS
ATMOSPHERE. DOING SO MAY RESULT IN SICKNESS OR DEATH. CONTAMINANTS,
WHICH ARE DANGEROUS TO YOUR HEALTH, INCLUDE THOSE THAT YOU MAY NOT BE
ABLE TO SEE OR SMELL.
LEAVE THE CONTAMINATED AREA IMMEDIATELY IF:
•
ANY PART OF THE SYSTEM BECOMES DAMAGED.
•
AIRFLOW INTO THE RESPIRATOR HEADPIECE DECREASES OR STOPS.
•
THE ALARM SIGNAL OF LOW BATTERY IS ON: RED LED FLASHES AND BUZZER
BEEPS.
•
BREATHING BECOMES DIFFICULT.
•
YOU FEEL DIZZY OR YOUR VISION IS IMPAIRED.
•
YOU TASTE OR SMELL CONTAMINANTS.
•
YOUR FACE, EYES, NOSE OR MOUTH BECOME IRRITATED.
•
YOU SUSPECT THAT THE CONCENTRATION OF CONTAMINANTS MAY HAVE
REACHED LEVELS AT WHICH THIS RESPIRATOR SYSTEM MAY NO LONGER PROVIDE
ADEQUATE PROTECTION.
Incorrect
Correct
Incorrect