STORAGE
Store your respirator at room temperature in a dry area that is protected from exposure to hazardous
contaminants.
TROUBLESHOOTING
Use the table below to help identify possible causes and corrective actions for problems you may experience.
Problem
Possible Cause
Corrective Action
Poor visibility through
visor
Visor is coated with debris.
Visor is scratched.
Wipe debris off.
Dispose of hood and replace it with new
hood.
Continuous low voltage
alarm sounds upon
blower activation
Battery is not charged.
Leave work area immediately.
Rechargeable Battery:
Switch to a fully charged battery, or
recharge.
Non-rechargeable Battery:
Replace Battery
Alkaline Battery Adaptor:
Install 5 new Duracell D-cell batteries
Low airflow
Battery needs charging.
Cartridges are loaded.
Filter plug not removed.
PAPR blower malfunction.
Leave work area immediately switch to fully
charged rechargeable battery, or a new non-
rechargeable battery.
Replace Cartridges.
Remove plug and install third CBRN filter.
Switch to a different blower unit.
Blower gasket is raised,
twisted, or has any
visible surface defects
Gasket is not properly seated
into the blower and may produce
a leak path
Contact ILC Dover Customer Service
Department immediately
1-800-631-9567
Blower housing is
cracked
Battery pack is cracked
Mishandling of the equipment
Improper use of the equipment
Excessive use/and or damage
Leave work area immediately and replace
with a new blower or battery pack.
Dispose damaged blower or battery and
replace.
Dents, Tears, Holes, or
Cracks in the Hood
Assembly or Breathing
Tube
Mishandling of the equipment
Improper use of the equipment
Not following the decon
procedures properly
Excessive wear/ and or damage
Leave work area immediately to prevent
contaminated air from entering the hood or
hose.
Dispose damaged hood or hose and replace it
with a new hood or hose.