![ILC Dover S-5000 Series Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/ilc-dover/s-5000-series/s-5000-series_user-instruction-manual_2043296009.webp)
- 8 -
S-2018
REV. D
GENERAL SAFETY INFORMATION
Intended Use:
The ILC Dover
SENTINEL XL™ PAPR CBRN
blower can be mounted to the Adjustable waist belt, Decon
and Quick Release Belt and Clip, or optional backpack, and is connected to the hood assembly via an integrated
flexible breathing tube. The ILC Dover
SENTINEL XL™ PAPR CBRN
must be used with the
S-2016
CBRN Cartridge.
The ILC Dover
SENTINEL XL™ PAPR CBRN
systems are intended to provide
respiratory protection against inhalation of certain gas and vapor chemical agents, biological particulates, and
radiological and nuclear dust particles. This respirator provides limited dermal (skin) protection to the head area
and eyes. This respirator does not protect against radioactive x-rays, gamma rays, or neutrons.
Note: Inspect emergency use respirators on a monthly basis.
∆
WARNING
THESE RESPIRATORS HELP PROTECT AGAINST CERTAIN AIRBORNE CONTAMINANTS.
MISUSE MAY RESULT IN INJURY OR DEATH. FOR PROPER USE, SEE SUPERVISOR, USER
INSTRUCTIONS, OR CALL ILC DOVER TECHNICAL SERVICE AT 1-800-631-9567. USE ONLY
ILC DOVER PARTS AND ACCESSORIES FOR THE ILC SENTINEL XL™ PAPR CBRN SYSTEM
AS DESCRIBED IN THESE USER INSTRUCTIONS.
ALWAYS DON THE RESPIRATOR SYSTEM PROPERLY AND IN AN UNCONTAMINATED
AREA.
DO NOT REACH YOUR HAND INTO THE FACE PIECE IN AREAS WHERE THE AIR IS
CONTAMINATED. LEAVE THE CONTAMINATED AREA AND CLEAN CONTAMINANTS
FROM YOUR HANDS BEFORE REACHING INSIDE THE HOOD.
IF YOU DISCOVER ANY OF THE WEAR AND DAMAGE DESCRIBED IN THE
TROUBLESHOOTING SECTION OF THIS USER INSTRUCTION, DISCARD COMPONENT AND
REPLACE IT WITH A NEW ONE. FAILURE TO DO SO MAY ADVERSELY AFFECT
RESPIRATOR PERFORMANCE AND RESULT IN SICKNESS OR DEATH.
BEFORE USE, THE WEARER MUST READ AND FULLY UNDERSTAND THESE USER
INSTRUCTIONS. KEEP THIS INSERT FOR FUTURE REFERENCE. IF YOU HAVE ANY
DOUBTS ABOUT THE APPLICABILITY OF THESE RESPIRATOR SYSTEMS TO YOUR JOB
SITUATION, CONSULT AN INDUSTRIAL HYGIENIST OR CALL THE ILC DOVER TECHNICAL
SERVICE LINE.
Use the ILC Dover
SENTINEL XL™ PAPR CBRN
for:
The ILC Dover
SENTINEL XL™ PAPR CBRN
systems are intended to provide respiratory protection against
inhalation of certain gas and vapor chemical agents, biological particulates, and radiological and nuclear dust
particles. This respirator provides limited dermal (skin) protection to the head area and eyes. This respirator
does not protect against radioactive x-rays, gamma rays, or neutrons.
Never use the ILC Dover
SENTINEL XL™ PAPR CBRN
for:
Atmospheres where oxygen concentration is below 19.5%, where concentrations of contaminants are:
unknown; immediately dangerous to life or health (IDLH); exceed applicable local standards or OSHA
standards for maximum use concentrations for the respirator, whichever is lower. Refer to additional
limitations and cautions under NIOSH Cautions and Limitations.
Содержание S-5000 Series