68
To change the Voltage mode from Auto to High press the Change soft key to
toggle between the two selections. To accept the selection, press the Enter soft
key. To cancel the selection, press the Esc soft key. You must press the Enter
soft key to accept the range. To transition into the next parameter of frequency
output you must press the Next soft key if you do not change the voltage setting.
If you wish to bypass editing this parameter and move to the next parameter you
can press the Prev or Next soft key.
4.6.6 Editing Frequency
Use the
,
soft keys to navigate to the Frequency parameter (only selectable
for AC output). Pressing the Edit soft key will provide the following screen:
Frequency = indicates the frequency currently programmed into the instrument.
Frequency Range: 40.0
– 1000 Hz indicates the frequency range that can be
programmed into the instrument.
To change the frequency, use the numeric keypad and type the frequency. Once
you type in a number a shaded black box (■) will begin blinking acknowledging
the parameter is being changed. Press the Enter soft key to accept the
parameter, or press the Esc key to move back to the Frequency Parameter
screen. When the Enter soft key is pressed the frequency is accepted and you
transition into the next parameter: Transient.
If you wish to bypass editing this parameter and move to the next parameter you
can press the Prev or Next soft key.
4.6.7 Editing Transient * (PROGRAM Mode only)
Use the
,
soft keys to navigate to the Transient parameter (only selectable for
AC output). Pressing the Edit soft key will provide the following screens: