Commissioning

Maintenance and cleaning

The equipment is maintenance-free. It is only subject to the 
natural wear and tear of components and their statistical 
failure rate.

Cleaning

Disconnect main plug prior to 
cleaning!

Use only cleaning agents which have been approved by 

IKA

®

 to clean the instrument. 

Dirt

Cleaning agent

Dye

isopropyl alcohol

Construction material   water containing tenside/isopropyl alcohol
Cosmetics

water containing tenside/isopropyl alcohol

Foodstuffs

water containing tenside

Fuel

water containing tenside

For materials which are not listed, please request informa-
tion from 

IKA

®

.

Wear protective gloves during cleaning the instrument.

Electrical devices may not be placed in the cleansing agent for 
the purpose of cleaning.

Do not allow moisture to get into the equipment when 
cleaning.

Before performing a non-recommended method of clean-
ing or decontamination, the user must ascertain with 

IKA

®

 

that this method will not destroy the instrument.

Maintenance

• Remove the top cover: by unscrewing the 4 screws on 

bottom.

• Examine hoses visually for cracks. If cracks have developed 

or the hose becomes brittle, replace with suitable new 
ones.

• To clean the housing of the device, use only water with a 

detergent that contains tensides, or use isopropylalcohol 
for stubborn soiling.

Connect  vacuum hose from inlet nozzle to recipient. Plug 
in power socket to mains and flip rocker switch (

A

, see 

Fig. 

1

) to “

I

” position to switch on the device.

Unscrew the 4 screws

View without the top cover

Fig. 4

Fig. 5

Observe the ambient conditions (temperature, humidity etc) 
listed under technical data.

Содержание MVP 10 basic

Страница 1: ...IKA MVP 10 basic MVP 10 basic 022016 20000004618...

Страница 2: ...mation which is important for proper use and ensuring that the operations of the instrument are performed efficiently and for using the instrument Failure to observe this information may result in ina...

Страница 3: ...the Accessories chapter Only authorized personnel are allowed to disassemble the appliance The device can only be disconnected from the power sup ply network by pulling out the mains plug or the conn...

Страница 4: ...ic pressure air to be pushed into the chamber The air in this chamber is then pushed out from the vacuum chamber through a different route gas outlet with the use of valves These periodic movements of...

Страница 5: ...a vacuum load device IKA MVP 10 basic vacuum pump standalone IKA MVP 10 basic Fig 2 Electrical connections Vacuum hose Mains power Recipient Outlet Inlet Pump control Vacuum Controller Magnetic Valve...

Страница 6: ...in the cleansing agent for the purpose of cleaning Do not allow moisture to get into the equipment when cleaning Before performing a non recommended method of clean ing or decontamination the user mu...

Страница 7: ...ballast valve refer to gure below Open Gas ballast valve is open when the notch on the cap is aligned with the notch on the nozzle Gas ballast valve can be closed by rotating cap at least 90 When gas...

Страница 8: ...ks Valves not seated properly incorrect orientation or damaged Contact IKA service department Diaphragm not seated in bore properly or damaged Contact IKA service department Incorrect washer con gurat...

Страница 9: ...tor protection Thermal cutout Operation at a terrestrial altitude m max 2000 Materials in contact with medium Components Wetted parts Vacuum crater insert PTFE Carbon reinforced Vacuum crater ETFE Car...

Отзывы: