![Ihse Draco tera 480 Series Скачать руководство пользователя страница 128](http://html.mh-extra.com/html/ihse/draco-tera-480-series/draco-tera-480-series_user-manual_623696128.webp)
Draco tera
128
2020-02-26
1. Insert the SFP modules into the matrix and connect the extender
according to the required application.
One extender will be created for each SFP module in the
Ext Units
list. The appropriate names always start with "UNI".
2. In order to configure a CON Unit, select one of the extenders in the
Ext Units
list that are physically connected to a USB CON Unit.
3. Select the item
UNI CON USB
in the
Type
selection box of the
Extender Type
tab and confirm your settings by pressing the
Apply
button.
4. Restart the I/O board upon request in the popup window by pressing
the
Yes
button.
5. In order to configure a CPU Unit, select one of the extenders in the
Ext Units
list that are physically connected to a USB CPU Unit.
6. Select the item
UNI CPU USB
in the
Type
selection box of the
Extender Type
tab and confirm your settings by pressing the
Apply
button.
7. Restart the I/O board upon request in the popup window by pressing
the
Yes
button.
8. The edited EXT Units for the respecting USB CON Units now have to
be either assigned to an existing CON Device or you have to create a
new CON Device by using the
New Device
button for an assignment
in the
Extender & Devices > CON Devices
menu.
9. The edited EXT Units for the respecting USB CPU Units now have to
be either assigned to an existing CPU Device or you have to create a
new CPU Device by using the
New Device
button for an assignment
in the
Extender & Devices > CON Devices
menu.
10. If you use parallel operation within the matrix, set the
Release Time
in the
System Settings > Switch
menu to
10 s
or more (see Chapter
The USB extenders are completely configured now and can be used.