Initial operation
Operating Instructions of the dryve D3 V0.0
9/15
4.2
Motor rotation direction
For proper operation, it is necessary that the motor rotates in a defined direction.
For determination, please use the following procedure:
1.
View from the motor shaft to the motor
2.
Actuation of the button S2 for clockwise rotation
3.
Clockwise direction of rotation of the motor corresponds to a right-hand rotation
If the motor rotates counterclockwise, the polarity of the motor connecting cables must be changed.
4.3
Limit switch
Two different types of limit switches can be connected to the dryve D3.
•
Passive mechanical switches with NC functionality (NC - Normally Closed)
•
Active electronic proximity switches with NC functionality in PNP interconnection (NC - Normally Closed)
Connected limit switches are supplied via the supply voltage (X2.1) connected to the dryve D3
For both types, different connection options must be taken into account.
Mechanical switches
The switches are connected to a voltage output and the respective signal input.
The right limit switch is connected to X3.1 and X3.2, the left to X3.4 and X3.5.
Electronic switches
The switches must be connected to a voltage output, the signal input and 0 V respectively.
The supply voltage of the right limit switch is connected to X3.1, the output signal to X3.2 and 0 V to X3.3. The supply voltage of
the left limit switch is connected to X3.4, the output signal to X3.5 and 0 V to X3.6.
In order to guarantee a logical and safe function, the limit switches must be assigned correctly to the respective running direc-
tion. A functionally connected, non-activated limit switch is indicated by a green LED below the respective direction button.
If a limit switch becomes active, the LED 1 below the respective direction button goes out. Please check that the LED 1 below
the left S1 button at the left limit switch also turns off. A test can also be carried out without driving the motor. If the connected
logic is not correct, the positions of the limit switches must be interchanged.