Initial operation
Operating Instructions of the dryve D3 V0.0
10/15
4.4
External directional switch
Travel movements can be remotely controlled via an external wiring.
For this purpose, normally-open (NO) passive switching contacts are connected to X4.1 and X4.2 as well as X4.3 and X4.4.
These switching contacts can be push buttons, relays and also optocouplers. A higher-level control system can be used via po-
tential-free contacts. The function is identical to the function of the buttons S1 and S2.
If a button combination for left-hand/right-hand rotation with only 3 connecting cables is used, then X4.2 and X4.4 must be
bridged. The common cable of the button combination must be connected to these bridged connections.
The buttons for left and right are connected to X4.1 and X4.3 respectively
NOTE
No external potential must be connected to X4 as this may destroy the dryve D3.
4.5
Basic settings
In its delivery condition, all switches are set to "off" (down position).
4.5.1
Operating modes
Tip mode
The motor is moved to the left or right when button S1 or S2 is pressed. If the button is not pressed, the motor stops.
Start to end mode
The motor is moved to the left or right after pressing button S1 or S2.
The motor stops only when:
1.
One of the two buttons is pressed
2.
The movement encounters a block whose resistance is greater than the
Force
which the motor is allowed.
3.
The
Limit switch
is triggered at the end of the movement.