Caution 

This symbol and signal word refer to a potentially 
hazardous  situation  which  could  result  in 
personal  injury,  property  and  environmental 
damage if ignored. 

 

Caution 

This symbol and signal word refer to a potentially 
hazardous situation which could result in damage 
to the equipment if ignored. 

 

Info 

This  symbol  indicates  useful  information  and 
recommendations  as  well  as  measures  that  will 
prolong the value of your measuring and control 
system. 

 

1.2  Intended use of the device 

Use these installation and operating instructions, the identification on the rating 
plate and the technical data sheet to check whether the device is suitable for the 
intended  use/application.  The  device  complies  with  the  requirements  of  the 
European Pressure Equipment Directive 2014/68/EU. 

 

The device may only be used to indicate fill levels on containers. 

The maximum values of the pressure and temperature range of the device must be checked 
before  installation.  If  the  maximum  allowable  operating  values  of  the  device  are  lower  than 
those of the system on which it is to be installed, protective instruments for the device, such 
as pressure reducers or similar, must be provided to avoid limit situations.  The device may 
only be used in accordance with the information in these installation and operating instructions 
or for the parameters and applications agreed in the supply contract (see rating plate). The 
operator of the direct water level indicator is obliged to familiarise himself on the compatibility 
of the medium and the device. In case of doubt, contact the relevant installation manager or 
site manager. 

The correct installation position, alignment and flow direction of the device must be observed! 
Before  installing  the  IGEMA  product  on  boilers  or  containers,  it  is  essential  to  remove  all 
protective covers and, if necessary, the protective film from rating plates and sight glasses. 

 

 

 

Caution 

Содержание IGEMA SC32-SC132

Страница 1: ...Edition 03 2021 D 11 B 53616 EN 00 Installation and maintenance instruction IGEMA SC32 SC132 Sample cooler...

Страница 2: ...e Steam is our passion and we offer you the entire programme for the safe and economic operation of your plants especially in the steam and condensate sector Please read the installation and operating...

Страница 3: ...5 Exclusion of liability 8 2 Contents of the packaging 8 3 General 9 3 1 Note 9 3 2 General Safety Instructions 9 4 Transport and Storage 10 4 1 Safety instruction 10 5 Installation 11 5 1 Safety Ins...

Страница 4: ...4 Table of contents cont 7 Maintenance 14 7 1 Limiting Conditions 14 8 Products returning 15 8 1 Safety Instructions 15 9 Loss of warranty 15...

Страница 5: ...bove tasks IGEMA GmbH accepts no liability for damage to property or personal injury caused by unqualified persons or by failure to observe these installation and operating instructions If no sufficie...

Страница 6: ...The maximum values of the pressure and temperature range of the device must be checked before installation If the maximum allowable operating values of the device are lower than those of the system on...

Страница 7: ...been depressurised and that the pressure has been safely reduced to atmospheric pressure In principle no system should be regarded as unpressurized even if indicated by pressure measuring devices suc...

Страница 8: ...bH the applicable safety and environmental laws according to GGVSEB German ordinance on the national and international carriage of dangerous goods by road rail and inland waterways must always be obse...

Страница 9: ...solve with the help of this instructions please contact the supplier or the manufacturer The manufacturer reserves the right to change the design and material of this product without notice 3 2 Gener...

Страница 10: ...rotective measures against dirt Correct installation of the equipment is full responsibility of the contractor Sample coolers are designed to be applied in places protected from exposure to weather We...

Страница 11: ...ior to install check that the product is suitable for the intended application materials and pressure temperature ratings Before installing remove plastic covers placed on flanges or connection ends T...

Страница 12: ...12 5 4 Dimensions Pos Description Sample cooler 1 Sample intake 2 Cooling water intake 2a Colling water valve 3 Draining connection 4 Funnel to take a measuring jug 5 Sample outlet 5a Thermometer unit...

Страница 13: ...wing must be checked All works are completed The sample cooler is correctly installed All the necessary safety devices have been installed At start up the presence of small particles in the fluid dirt...

Страница 14: ...ly after a small period of time in order to condense or cool the remaining steam inside the sample cooler 6 3 Periodical checking 24 hours after the start up it is recommended to check the pipe connec...

Страница 15: ...bstances identified as hazardous or potentially hazardous must be provided with the information mentioned above 9 Loss of warranty LOSS OF WARRANTY Total or partial disregard of above instructions inv...

Страница 16: ...16 Antwerpener Str 1 Fon 49 2501 92424 0 48163 M nster Fax 49 2501 92424 99 Deutschland info igema com www igema com IGEMA GmbH...

Отзывы: