16
To turn the X90-OPUS off, press and hold the On/Off button
for one second. All four LED’s will quickly flash three times
and the receiver will power down.
Collecting Static Data
OPUS and OPUS-RS
Additional information on OPUS-Static and OPUS-Rapid Static
can be found in the ‘OPUS’ section of this manual.
Prior to using the X90 OPUS receiver, charge the batteries to
insure that the static occupation is not interrupted by power
failure.
A fresh battery when new and fully charged will run the
receiver for 6-hours, for occupations longer than 4-hours
you should provide external power to the receiver with the
included battery clips (or the power supply.)
1.
Place a freshly charged battery into the
receiver.
2.
Place the receiver above the point you
want to survey.
3.
Rotate the receiver so the pushbutton
panel faces the North.
4.
Level the receiver.
5.
Record the ‘Vertical Height’ from the top
of the survey mark to the bottom of the
receiver; alternatively you may measure a
‘Slant Height’ to the blue rubber gasket.
6.
At a minimum, make a careful note of the
following items in your field book:
Start Time and Date
Instrument Height (HI)
PID (Point ID, Mark Name)
Description
Point
Description
HI
Start Time
End
1001
NW C Sec 14
2.0M V
9:45 am 1 March 2013