O3M area surveillance
24
8.1 Wiring 3D sensor
①
Power supply and CAN bus
M12 connector, A-coded, 5 poles
4
2
1
3
5
1 Shield
2 9���32 V DC
3 GND
4 CAN high
5 CAN low
②
Ethernet
M12 socket, D-coded, 4 poles
1
Ethernet TD +
2
Ethernet RD +
3 Ethernet TD -
4 Ethernet RD -
S Shield
③
MCI - Modulation and Communication Interface
Connection sensor - illumination unit
Fig� 14: Wiring 3D sensor, back
4
④
Analogue video output (PAL)
M12 socket, A-coded, 5 poles
1 Shield
2 n�c�
3 GND
4
FBAS (video)
5 n�c�
Fig� 15: Wiring 3D sensor, bottom
8.2 Wiring illumination unit
①
MCI - Modulation and Communication Interface
Connection sensor - illumination unit
Only use original ifm cables E3M120, E3M121, E3M122 or E3M123�
②
Power supply
M12 connector, A-coded, 4 poles
1 GND
2 9���32 V DC
3 9���32 V DC
4 GND
Fig� 16: Wiring illumination unit, bottom