19
O3M area surveillance
UK
The table contains exemplary values for various mounting positions (depending on the mounting location,
taking into account a minimum distance A in front of the 3D sensor).
Mounting height
h
[m]
Recommended
inclination angle
α [°]
Min�
distance
A
[m]
Max�
distance
B
[m]
Width at the
vehicle
C
[m]
Width at the end of
the field of view
D
[m]
2D
3D
2D
3D
1�6
20
0�5
8
2�2
1�5
30
19�5
2
29
0�6
5�6
3
2
20
13
2�2
34
0�6
4�6
3�6
2�4
17
11
2�4
38
0�7
4�2
4�3
2�8
16
10
2�6
42
0�7
3�9
4�9
3�2
15
9�8
2�8
46
0�7
3�6
5�5
3�6
14�5
9�5
3
48
0�7
3�5
6
4
14�5
9�5
►
Mount the 3D sensor as centrally as possible at the front of the vehicle roof using the E3M102 bracket
> If central mounting of the 3D sensor is not possible: Use the zone definition to compensate for the
deviation (→ "10.1.5 Zone definition - expert settings").
Fig� 8: 3D sensor and illumination unit mounted side by side
►
Viewed from the front, mount the illumination unit directly to the right of the 3D sensor using the
> The devices are calibrated for mounting directly next to each other� Otherwise, the recognition rate of
objects is reduced�
►
Connect the 3D sensor to the illumination unit via the MCI connection cable�
Keep the area illuminated by the illumination unit free from any obstructions in a close range (up to
50 cm).
►
Use cables with strain relief�