background image

Operating instructions 

Pressure sensor

PY929x

706215 / 00

 

 

08 / 2012

UK

Содержание efectro 500

Страница 1: ...Operating instructions Pressure sensor PY929x 706215 00 08 2012 UK ...

Страница 2: ...ter setting 10 9 2 Configure display optional 12 9 3 Set output signals 12 9 3 1 Set the output function 12 9 3 2 Set switching limits 12 9 4 User settings optional 13 9 4 1 Set delay for the switching outputs 13 9 4 2 Set switching logic for the switching outputs 13 9 4 3 Set the damping for the switching outputs 13 9 5 Service functions 13 9 5 1 Read min max values for system pressure 13 9 5 2 R...

Страница 3: ...e read the product description prior to set up of the unit Ensure that the product is suitable for your application without any restrictions If the operating instructions or the technical data are not adhered to personal injury and or damage to property can occur Check the compatibility of the product materials chapter 12 Technical data with the media to be measured in all applications Use in gase...

Страница 4: ...t be exceeded Even if the bursting pressure is exceeded only for a short time the unit may be destroyed NOTE risk of injury Use in gases at pressures 25 bar only on request 4 Function 4 1 Communication parameter setting evaluation The unit displays the current process value It generates 2 output signals according to the parameter setting OUT1 Switching signal for process value IO Link OUT2 2 optio...

Страница 5: ...ormally open OUx Fno fig 2 Window function normally closed OUx Fnc fig 2 The width of the window can be set by means of the difference between SPx and rPx SPx upper value rPx lower value 1 2 P system pressure HY hysteresis FE window 4 3 Diagnostic function Output 2 is used as diagnostic output based on the DESINA specification if OU2 dESI If there is no fault the output is switched and carries UB ...

Страница 6: ...tional and international regulations for the installation of electrical equipment must be adhered to Voltage supply to EN 50178 SELV PELV Disconnect power Connect the unit as follows 2 x positive switching 2 x negative switching Pin 1 Ub Pin 3 Ub Pin 4 OUT1 Binary switching output IO Link Pin 2 OUT2 Binary switching output if OU2 Hno Hnc Fno or Fnc Diagnostic output if OU2 dESI Core colours of ifm...

Страница 7: ...LED 7 LED 8 switching state of the corresponding output 9 Alphanumeric display 4 digits Display of the current system pressure Indication of the parameters and parameter values 10 Set button Setting of the parameter values scrolling by holding pressed incrementally by pressing once 11 Mode Enter button Selection of the parameters and acknowledgement of the parameter values ...

Страница 8: ...8 8 Menu 8 1 Menu structure ...

Страница 9: ... Switching signal for the pressure limit values hysteresis function H or window function F either normally open no or normally closed nc Diagnostic signal OU2 dESI EF Extended functions opening of menu level 2 Uni Standard unit of measurement for system pressure HI Maximum value memory for system pressure LO Minimum value memory for system pressure only PY9294 dS1 dS2 Switch on delay for OUT1 OUT2...

Страница 10: ... pressing once or scrolling by holding pressed Numerical values are incremented continuously For reducing the value let the display move to the maximum setting value Then the cycle starts again at the minimum setting value 3 Acknowledge parameter value Press Mode Enter briefly The parameter is displayed again The new setting value is stored Set other parameters Start again with step 1 Finish param...

Страница 11: ...splayed here Uni With the user interface of the program ifm Container Activate the EF button If menu level 2 is protected by an access code the input field for the code no is activated Enter the valid code no Locking unlocking The unit can be locked electronically to prevent unintentional settings Make sure that the unit is in the normal operating mode Press Mode Enter Set for 10 s Loc is displaye...

Страница 12: ... OFF The display is switched off in the operating mode 9 3 Set output signals 9 3 1 Set the output function Select OU1 and set the function Hno hysteresis function NO Hnc hysteresis function NC Fno window function NO Fnc window function NC Select OU2 and set the function Hno hysteresis function NO Hnc hysteresis function NC Fno window function NO Fnc window function NC dESI output 2 is used as a d...

Страница 13: ...tatus in milliseconds The following fixed values can be set they define the switching frequency f of the output dAP 3 6 10 17 30 60 125 250 500 f Hz 170 80 50 30 16 8 4 2 1 9 5 Service functions 9 5 1 Read min max values for system pressure Select HI or Lo briefly press Set HI maximum value LO minimum value Delete memory Select HI or LO Press SET and keep it pressed until is displayed Press Mode E...

Страница 14: ...arameter is displayed Press Set briefly The unit displays the corresponding parameter value for approx 15 s After another 15 s it returns to the Run mode 10 2 Error indications OL Overload pressure above measuring range UL Underload pressure below measuring range SC1 Short circuit in OUT1 SC2 Short circuit in OUT2 SC Short circuit in both outputs Err Flashing internal fault The output concerned is...

Страница 15: ... 9 95 0 05 PY9293 bar 0 2 25 0 0 1 24 9 0 1 PSI 4 362 2 360 2 MPa 0 02 2 50 0 01 2 49 0 01 PY9294 bar 0 90 10 00 0 95 9 95 0 05 PSI 12 145 13 144 1 MPa 0 090 1 000 0 095 0 995 0 005 ΔP step increment 11 Technical data and scale drawing The technical data and the scale drawing of the current unit version can be found in the data sheet of the respective unit at www ifm com search function enter the ...

Страница 16: ... setting SP1 25 VMR rP1 23 VMR OU1 Hno OU2 dESI SP2 75 VMR rP2 73 VMR dS1 0 0 dr1 0 0 dS2 0 0 dr2 0 0 P n PnP dAP 60 diS d2 Uni bAr The indicated percentage of the final value of the measuring range VMR of the corresponding sensor is set in bar ...

Страница 17: ...17 UK ...