15
UK
10.3 Setting ranges
SP1 / SP2
rP1 / rP2
ΔP
min
max
min
max
PY9291
bar
2
250
1
249
1
PSI
40
3620
20
3600
20
MPa
0�2
25�0
0�1
24�9
0�1
PY9292
bar
1�0
100�0
0�5
99�5
0�5
PSI
20
1450
10
1440
10
MPa
0�10
10�00
0�05
9�95
0�05
PY9293
bar
0�2
25�0
0�1
24�9
0�1
PSI
4
362
2
360
2
MPa
0�02
2�50
0�01
2�49
0�01
PY9294
bar
-0�90
10�00
-0�95
9�95
0�05
PSI
-12
145
-13
144
1
MPa
-0�090
1�000
-0�095
0�995
0�005
ΔP = step increment
11 Technical data and scale drawing
The technical data and the scale drawing of the current unit version can
be found in the data sheet of the respective unit at www.ifm.com → search
function (enter the order number)�