10
9 Parameter setting
During parameter setting the unit remains in the operating mode� It continues its
monitoring functions with the existing parameters until the parameter setting has
been completed�
9.1 General parameter setting
3 steps must be taken for each parameter setting:
1
Select parameter
►
[Press [Mode/Enter] until the
requested parameter is displayed
.
2
Set parameter value
►
Press [Set] and keep it pressed�
> Current setting value of the
parameter flashes for 5 s�
> After 5 s: setting value is changed:
incrementally by pressing once or
scrolling by holding pressed�
Numerical values are incremented continuously� For reducing the value: let the
display move to the maximum setting value� Then the cycle starts again at the
minimum setting value�
3
Acknowledge parameter value
►
Press [Mode/Enter] briefly�
> The parameter is displayed again�
The new setting value is stored�
Set other parameters
►
Start again with step 1�
Finish parameter setting
►
Press [Mode/Enter] several times until the current measured value is displayed or wait
for 15 s�
> The unit returns to the operating mode�
•
If [SLoc] is displayed when attempting a modification of a parameter value,
the sensor is locked via software� This locking can only be removed via a
parameter setting software�