3 Functions and features
The unit monitors the system pressure of machines and installations�
Applications
Type of pressure: relative pressure
Order no.
Measuring range
Permissible
overload pressure Bursting pressure
bar
PSI
bar
PSI
bar
PSI
PY9291
0���250
0���3625
400
5800
850
12300
PY9292
0���100
0���1450
300
4350
650
9400
PY9293
0���25
0���363
150
2175
350
5075
PY9294
-1���10
-14�5���145
75
1087
150
2175
MPa = bar ÷ 10 / kPa = bar × 100
Avoid static and dynamic overpressure exceeding the given overload
pressure by taking appropriate measures�
The indicated bursting pressure must not be exceeded�
Even if the bursting pressure is exceeded only for a short time, the unit
may be destroyed� NOTE: risk of injury!
Use in gases at pressures > 25 bar only on request�
4 Function
4.1 Communication, parameter setting, evaluation
•
The unit displays the current process value�
•
It generates 2 output signals according to the parameter setting�
OUT1
•
Switching signal for process value; IO-Link�
OUT2
2 options
•
Switching signal for process value�
•
Diagnostic signal (output 2 is inactive in case of a fault)�
•
The following functions are available via IO-Link (OUT1):
reading the current process value, changing the parameters and transferring
them to other units of the same type using parameter setting tools with IO-Link
capability (except the FDT service program ifm Container)�