14
10 Operation
After power on, the unit is in the Run mode (= normal operating mode)� It carries
out its measurement and evaluation functions and provides output signals
according to the set parameters�
Operation indication → chapter 7 Operating and display elements.
10.1 Read set parameters
►
Press [Mode/Enter] until the requested parameter is displayed�
►
Press [Set] briefly�
> The unit displays the corresponding parameter value for approx� 15 s� After
another 15 s it returns to the Run mode�
10.2 Error indications
[OL]
Overload pressure (above measuring range)�
[UL]
Underload pressure (below measuring range)�
[SC1]
Short circuit in OUT1*�
[SC2]
Short circuit in OUT2*�
[SC]
Short circuit in both outputs*�
[Err]
Flashing: internal fault
*The output concerned is switched off as long as the short circuit exists�
The messages SC1, SC2, SC, Err are shown even if the display is switched off�