1: Field coil
2: Measuring pipe
3: Electrode
4: Charge carrier in the medium
5: Magnetic field
Both electrodes must be wetted by the medium� Otherwise the signal
[SEnS] for empty pipe is provided, if empty pipe detection is enabled�
4.2 Processing of the measured signals
The unit displays the current process values�
It generates 2 output signals according to the parameter setting�
OUT1/IO-Link: 5 selection options
Parameter setting
-Switching signal for volumetric flow limit values
-or frequency signal for volumetric flow quantity
-or pulse signal for quantity meter
-or switching signal for preset counter
-or switching signal for empty pipe detection
OUT2: 6 selection options
Parameter setting
-Switching signal for volumetric flow limit values
-or switching signal for temperature limit value
-or analogue signal for volumetric flow quantity
-or analogue signal for temperature
-or input for external reset signal (InD)
-or switching signal for empty pipe detection