CabinetModule CR2014
8
Parameter setting
6
Automatic saving
6.1
Automatic saving of the communication and device parameters can be activated or
deactivated by means of the “save parameter” entry (object directory, index 1010,
S-Idx 01)�
● Value 0x00:
There is no automatic saving� Changed parameters are only valid until the device
is switched off or until the next reset�
● Value 0x01:
Changed parameters will be saved if the string “save” is written in S-Idx 01�
Otherwise changed parameters are only valid until the device is switched off or
until the next reset�
● Value 0x02:
Changed parameters are saved automatically�
Restoring the factory setting
6.2
With the function “restore” (object directory, index 1011, subindex 01) the factory
default values can be restored (except for the baud rate and the node ID)� They
become valid with the next power on�